Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
A Device Fails to Be Logged In Through the Console Port

A Device Fails to Be Logged In Through the Console Port

Fault Description

Login through the console port fails.

Possible Causes

  • Parameters of the serial port are incorrectly configured.
  • The connected port is incorrectly configured.
  • Physical attributes of the serial port on the PC are different from attributes of the console port on the device.
  • Cables are not firmly connected on the serial interface.

Troubleshooting Procedure

  1. Check whether the serial port parameters are correctly configured. (The third-party software SecureCRT is used as an example here.)

    Check whether a correct serial port is connected. Some PCs provide multiple serial ports with corresponding numbers. When connecting a serial port, ensure that the correct serial port number is selected.

    Check that the serial port settings on the PC are the same as the console port settings on the device, as shown in Figure 29-12. The default console port settings are as follows:
    • Baud rate: 9600
    • Data bits: 8
    • Stop bits: 1
    • Parity: None
    • Flow control: None
    Figure 29-12  Setting the connected port and communication parameters
  2. Check whether the serial cable is securely connected. If necessary, replace the current cable with a properly-functioning one.

  3. If the fault persists, collect error information and contact technical support personnel.