Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Dynamic BFD Session Fails to Be Created

Dynamic BFD Session Fails to Be Created

Common Causes

This fault is commonly caused by one of the following:
  • BFD is not enabled for the protocol.

  • The route to the peer of the BFD session does not exist in the routing table.

  • The interface is prohibited from creating a BFD session.

Troubleshooting Flowchart

Figure 23-6  Troubleshooting flowchart for the fault that a dynamic BFD session fails to be created

Troubleshooting Procedure

Context

NOTE:

Save the results of each troubleshooting step. If your troubleshooting fails to correct the fault, you will have a record of your actions to provide Huawei technical support personnel.

Procedure

  1. Run the display current-configuration configuration bfd command to check that BFD is enabled for a protocol.

    • If BFD is not enabled for a protocol, enable BFD. Then, go to Step 2.

    • If BFD is enabled, go to Step 3.

  2. Run the display bfd session all command to view the state field.

    • If the state field in the command output is Up, it indicates that the BFD section has been created.

    • If the state field in the command output is not Up, go to step 3.

  3. Run the display ip routing-table command to check whether the route of the link detected by the BFD session exists.

    • If the route exists, go to step 4.

    • If the route does not exist, the BFD session associated with the protocol fails to be created. see the section The Ping Operation Fails.

  4. Run the interfaceinterface-typeinterface-number command to enter the view of the existing interface, then run the display this command to check that a command is configured to disable an interface to dynamically create a BFD session.

    • If such a command is configured, Run the undo ospf bfd block command to enable the interface to dynamically create a BFD session. Then, run the display bfd session all command to check whether the BFD session is Up. If the session is not up, go to step 5.

    • If such a command is not configured, go to step 5.

  5. If the fault persists, collect the following information and contact technical support personnel.

    • Results of the preceding troubleshooting procedure.
    • Configuration files, log files, and alarm files of the devices.

Translation