Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Communication on an E1 Interface Is Abnormal

Communication on an E1 Interface Is Abnormal

Fault Description

The protocol status of an E1 interface flaps between Up and Down, and traffic statistics on the interface show many CRC-error packets.

Run the display interface Serial command in the system view to check the state and packet statistics on the E1 interface.

[Huawei] display interface Serial 1/0/0                                         
Serial1/0/0 current state : UP                                                        
Line protocol current state : UP                                                      
Last line protocol up time : 2012-02-13 10:16:53                                      
Description:to Shengting-R1                                                           
Route Port,The Maximum Transmit Unit is 1500, Hold timer is 10(sec)                   
Internet Address is 10.21.254.126/30                                                  
Link layer protocol is PPP                                                            
LCP opened, IPCP opened                                                               
Timeslot(s) Used: 0-31,  baudrate is 2048000 bps                                      
Last physical up time   : 2012-02-13 10:16:49                                         
Last physical down time : 2012-02-13 10:15:29                                         
Current system time: 2012-02-13 16:17:49                                              
Last 300 seconds input rate 59 bytes/sec 472 bits/sec 1 packets/sec                   
Last 300 seconds output rate 178 bytes/sec 1424 bits/sec 1 packets/sec                
Input: 22225 packets, 1484955 bytes                                                   
Length Error:            0,    Giants:                  0                             
CRC:           11, Alignments:              0                             
Aborts:                  0,  No Buffers:                0                             
Output: 42061 packets, 4043517 bytes                                                  
Total Error:             0,  Too Long Error:            0                             
Input bandwidth utilization  : 0.02%                                                  
Output bandwidth utilization : 0.13%                                                  

Possible Causes

  • The E1 interface card is not reliably grounded.

  • There are electromagnetic interference sources, such as an electric motor, transformer, and electric generator, near the E1 line.

  • The E1 line is deployed outdoors, and the E1 interface is damaged by lightning.

  • The E1 interface impedance is different from the cable impedance.

Troubleshooting Procedure

  1. A ground cable is delivered with the chassis in the package. Use this ground cable to connect the ground point on the chassis to an equipotential terminal in the equipment room. Ensure that the local and remote devices are on an equipotential plane.
  2. Keep the E1 line away from electromagnetic interference sources.
  3. If the E1 interface is damaged by lightning, contact technical support personnel through Collecting Information and Contacting Technical Support for repair service.
  4. The impedance of an E1 interface can be set to 120 ohm (requiring 120-ohm balanced cables) or 75 ohm (requiring 75-ohm unbalanced cables). Ensure that the cables used on the E1 interface match the impedance of the interface.
    • Use the following command to set the impedance of the E1 interface:
      [Huawei-Serial2/0/0] fe1 line-termination ?                                   
      75-ohm   75 ohm termination                                                  
      120-ohm  120 ohm termination                                                 
    • Use the following command to check the impedance of the E1 interface:
      [Huawei-Serial2/0/0] display fe1 Serial 2/0/0                                   
      Serial2/0/0                                                                          
      Basic Configuration:                                                                 
      Work Mode is E1 Fractional Framed, Cable type is 120 Ohm  balanced             
      Frame-format is NO-CRC4, Line Code is Hdb3                                           
      Source Clock is Slave, Data-coding is Normal                                         
      Idle code is 7E, Itf type is 7E, Itf number is 4                                     
      Loopback is Not Set                                                                  
      Idle code is 7E, Itf type is 7E, Itf number is 4                                     
      Alarm State:                                                                         
      Receiver alarm state is Loss-of-Signal                                               
      Transmitter is sending remote alarm                                                  
      Pulse density violation detected                                                     
      Historical Statistics:                                                               
      Data in current interval (0 seconds elapsed):                                        
      0 Line Code Violations, 0 Path Code Violations                                       
      0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins                        
      0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs               
      Total Data (last 24 hours):                                                          
      0 Line Code Violations, 0 Path Code Violations                                       
      0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins                        
      0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs               