Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Logging In to the Management Module CLI Through the Management IP Address of the Server Node

Logging In to the Management Module CLI Through the Management IP Address of the Server Node

Scenarios

Log in to the management module CLI through the iBMC management IP address on the server node.

Prerequisites

Conditions

The server has been powered on.

Data

  • IP address of the iBMC management network port on the server node
  • User name and password for logging in to the iBMC of the server node

Software

PuTTY.exe (third-party software)

Procedure

  1. Set the client address.

    1. Set the IP address, subnet mask, or route of the client to enable the client to interconnect with the iBMC management network port on the server node.

      On the client, choose Start > Run, enter cmd, and click OK. Then, run the Ping IP address of the aggregated management network port command to check whether the management network port is reachable.

  2. Log in to the iBMC WebUI of the server node.

    1. For details, see Logging In to the iBMC WebUI.

  3. Enable the transparent transmission function.

    1. In the navigation tree on the iBMC WebUI of the server node, choose Configure > Service Settings.

      The Service Settings page is displayed.

      NOTE:

      If the iBMC version is earlier than 2.01, the Port Settings page is displayed.

    2. Enable HMM SSH NAT and set Port to 30022, as shown in Figure A-23.
      Figure 9-23 Enabling the transparent transmission function

  4. Log in to the management module CLI.

    1. On the client, double-click PuTTY.exe.

      The PuTTY Configuration window is displayed, as shown in Figure A-24.

      Figure 9-24 PuTTY Configuration
    2. Set the login parameters.

      The parameters are described as follows:

      • Host Name (or IP address): Enter the IP address of the management network port, for example, 10.10.1.104.
      • Port: Retain the default value 30022.
      • Connection type: Retain the default value SSH.
      • Close window on exit: Retain the default value Only on clean exit.
      NOTE:

      After you set Host Name (or IP address) and then Saved Sessions and click Save, you can simply double-click the saved settings under Saved Sessions to log in to the server.

    3. Click Open.

      The PuTTY window is displayed. Then the message login as: is displayed, prompting you to enter a user name.

      NOTE:
      • If you log in to the server for the first time, the PuTTY Security Alert dialog box is displayed. If you trust this site, click Yes. The PuTTY window is displayed.
      • If the entered user name or password is incorrect during server login, PuTTY must be connected again.
    4. Enter the user name and password as prompted.
    5. Run the following command to check that Product Name is MM630 or MM650, which indicates that the transparent transmission function is configured successfully.

      ipmcget -d version

      The command output is as follows:

      iBMC:/->ipmcget -d version 
      ------------------- iBMC INFO -------------------
      IPMC               CPU:           Hi1710
      IPMI           Version:           2.0
      CPLD           Version:           (U30)0.02
      Active iBMC    Version:           (U9)2.80
      Active iBMC      Build:           001
      Active iBMC      Built:           22:11:24 Mar 14 2018
      Backup iBMC    Version:           2.78
      SDK            Version:           3.11
      SDK              Built:           10:19:29 Mar  9 2018
      Active Uboot   Version:           2.1.07 (Dec 21 2017 - 18:01:59)
      Backup Uboot   Version:           2.1.07 (Dec 21 2017 - 18:01:59)
      IPMB           Address:           0x10
      ----------------- Product INFO -----------------
      Product             ID:           0x0003
      Product           Name:           MM650
      -------------- Mother Board INFO ---------------
      Mainboard      BoardID:           0x0068
      Mainboard          PCB:           .A
      -------------- FAN Board INFO ------------------
      BC21FIMD       BoardID:           0x0059
      BC21FIMD           PCB:           .A
      -------------------- PS INFO -------------------
      PS1            Version:           DC: 105  PFC: 104
      PS2            Version:           DC: 105  PFC: 104
      -------------- Backplane INFO ------------------
      BC21BKPN       BoardID:           0x0044
      BC21BKPN           PCB:           .A