Command Reference 10

OceanStor 18500 V3 and 18800 V3 Mission Critical Storage System V300R003

"Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions."
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
remove notification receiver

remove notification receiver

Function

The remove notification receiver command is used to remove an email or phone number that is used to receive alarm notifications.

Format

remove notification receiver alarm_level=? { email_receiver_list=? | message_receiver_list=? }

Parameters

Parameter

Description

Value

alarm_level=? Alarm severity.

The value can be "warning", "major" or "critical". You can run the "show notification email" or "show notification sms" command to check the severity.

email_receiver_list=? List of emails that receive alarms.

Multiple email addresses can be specified. You can run the "show notification email" command to check the email list.

message_receiver_list=? List of phone numbers that receive alarm notifications.

Multiple phone numbers can be specified. You can run the "show notification sms" command to check the phone number list.

Level

Administrator

Usage Guidelines

None.

Example

  • Removing "joe@company.com" that receives warning alarms or alarms of higher severities from the recipient emails of alarm notifications.

    admin:/>remove notification receiver alarm_level=warning email_receiver_list=joe@company.com
    WARNING: You are about to delete the recipient email or phone number of email- or SMS-based alarm notifications. The recipient email or phone number cannot receive notifications after being deleted.
    Suggestion: Before performing this operation, ensure that it is allowed to delete the recipient email or phone number.
    Have you read warning message carefully?(y/n)y
    Are you sure you really want to perform the operation?(y/n)y
    Command executed successfully.
  • Removing 13812345678 that receives warning alarms or alarms of higher severities from the recipient phone numbers of alarm notifications.

    admin:/>remove notification receiver alarm_level=warning message_receiver_list=13812345678 
    WARNING: You are about to delete the recipient email or phone number of email- or SMS-based alarm notifications. The recipient email or phone number cannot receive notifications after being deleted.
    Suggestion: Before performing this operation, ensure that it is allowed to delete the recipient email or phone number.
    Have you read warning message carefully?(y/n)y
    Are you sure you really want to perform the operation?(y/n)y
    Command executed successfully.

System Response

None