No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Parts Replacement 12

OceanStor 18500 V3 and 18800 V3 Mission Critical Storage System V300R003

This document describes the procedure for replacing the parts of storage system in terms of safety operations, preparations, and precautions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Replacing an Indicator Board

Replacing an Indicator Board

This section explains how to replace an indicator board.

Prerequisites

  • A replacement indicator board is ready.
  • The indicator board that you want to replace has been located. The cabinet door has one upper and one lower indicator boards, which can be replaced using the same method. This section shows how to replace an upper indicator board.

Precaution

Remove and insert the indicator board with even force. Excessive force may damage the appearance or connectors of the indicator board.

Tools and Materials

  • ESD wrist strap
  • ESD bag
  • Label
  • Phillips screwdriver

Procedure

  1. Wear an ESD wrist strap. Open the front cabinet door.
  2. Remove the indicator board to be replaced.
    1. Use a screwdriver to remove the screws of the indicator board's cover, slightly lift the cover, and then remove it, as shown in Figure 13-7.

      Figure 13-7  Removing the indicator board's cover

    2. Remove cables connected to the indicator board.

      NOTE:

      Two conversion cables need to be removed for an upper board. Two conversion cables and two input cables need to be removed for a lower board.

    3. Use a screwdriver to remove the screws of the indicator board and remove the board from the cabinet door.
  3. Install the indicator board.
    1. Take the replacement indicator board out of the ESD bag.
    2. Install the indicator board to the cabinet and fix it using screws.
    3. Connect cables.
    4. Install the indicator board's cover and fix it using screws.
  4. If the cabinet indicator is green, the indicator board is replaced successfully.

Follow-up Procedure

After the indicator board is replaced, label it for subsequent operations.

Translation
Download
Updated: 2019-05-15

Document ID: EDOC1000084105

Views: 21338

Downloads: 140

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next