Product Description 15

OceanStor 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3 Storage System V300R003

This document introduces the storage system from the aspects of the market position, features, architecture, technical specifications, production configuration, environment requirement, standard compliance, and granted certifications.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Indicator Introduction

Indicator Introduction

After a disk enclosure is powered on, you can check the current operating status of the disk enclosure by viewing its indicators.

Indicators on the Front Panel

Figure 4-114 shows the indicators on the front panel of a high-density disk enclosure.
Figure 4-114  Indicators on the front panel of a high-density disk enclosure

1

High-density disk enclosure Location indicator

2

High-density disk enclosure overtemperature Alarm indicator

3

High-density disk enclosure internal module Alarm indicator

4

High-density disk enclosure rear module Alarm indicator

5

High-density disk enclosure Power indicator

6

High-density disk enclosure Alarm indicator

Table 4-73 describes the indicators on the front panel of a high-density disk enclosure.

Table 4-73  Description of the indicators on the front panel of a high-density disk enclosure

Module

No.

Indicator

Status and Description

System enclosure

1

High-density disk enclosure Location indicator

  • Blinking blue: The high-density disk enclosure has been located.
  • Off: The high-density disk enclosure is not located.

2

High-density disk enclosure overtemperature Alarm indicator

  • Steady red: The temperature of the high-density disk enclosure is too high.
  • Off: The temperature of the high-density disk enclosure is within the normal range.

3

High-density disk enclosure internal module Alarm indicator

  • Steady red: Internal disk modules of the high-density disk enclosure are faulty.
  • Blinking red: Internal disk modules of the high-density disk enclosure is about to fail.
  • Off: Internal disk modules are running correctly.

4

High-density disk enclosure rear module Alarm indicator

  • Steady red: The number of rear field replaceable units (FRUs) is fewer than half of that in standard configuration or rear FRUs are faulty.
    NOTE:

    Modules on the rear of the high-density disk enclosure include power modules, fan modules, and expansion modules.

  • Off: Rear FRUs are running correctly.

5

High-density disk enclosure Power indicator

  • Steady green: The high-density disk enclosure is powered on.
  • Off: The high-density disk enclosure is not powered on.

6

High-density disk enclosure Alarm indicator

  • Steady red: An alarm is generated in the high-density disk enclosure.
  • Off: The high-density disk enclosure is running correctly.

Indicators on the Rear Panel

Figure 4-115 shows the indicators on the rear panel of a high-density disk enclosure.
Figure 4-115  Indicators on the rear panel of a high-density disk enclosure

1

Running/Alarm indicator of the power module

2

Indicator of a mini SAS HD expansion port

3

Fan module Running/Alarm indicator

4

Expansion module Alarm indicator

5

Expansion module Power indicator

   
Table 4-74 describes the indicators on the rear panel of a high-density disk enclosure.
Table 4-74  Description of the indicators on the front panel of a high-density disk enclosure

Module

No.

Indicator

Status and Description

Power module

1

Running/Alarm indicator of the power module

  • Steady green: The power module is working correctly.
  • Off: The power module is power off, or undervoltage, overvoltage, overtemperature, or short-circuit occurs.

Expansion module

2

Indicator of a mini SAS HD expansion port

  • Steady blue: The link is up and the data transfer rate is 4 x 6 Gbit/s.
  • Steady green: The link is up and the data transfer rate is 4 x 3 Gbit/s.
  • Steady red: The expansion port is faulty.
  • Off: The link is down.

Fan module

3

Fan module Running/Alarm indicator

  • Steady green: The fan module is running correctly.
  • Steady red: The fan module is faulty.
  • Off: The fan module is not powered on.

Expansion module

4

Expansion module Alarm indicator

  • Steady red: The expansion module is faulty.
  • Off: The expansion module is not powered or is running correctly.

5

Expansion module Power indicator

  • Steady green: The expansion module is running correctly.