Administrator Guide 15

OceanStor 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3 Storage System V300R003

Routine maintenance activities are the most common activities for the storage device, including powering on or off the storage device, managing users, modifying basic parameters of the storage device, and managing hardware components. This document applies to the system administrators who are responsible for carrying out routine maintenance activities, monitoring the storage device, and rectifying common device faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Logging In to the DeviceManager (Using a Tablet)

Logging In to the DeviceManager (Using a Tablet)

You can use a tablet to log in to a storage system and conduct basic maintenance operations, such as checking alarms, performance statistics, and the basic information of the storage system.

Prerequisites

A Wi-Fi network that is connected to the storage system's management network is available onsite.

Context

  • DeviceManager only supports TSL protocols (including TLS 1.0, TLS 1.1, and TLS 1.2).
  • Customers can use a tablet to log in to the storage system through their wireless routers. You can use iPad Air (Safari) and HUAWEI MediaPad 10 FHD (Chrome) to log in to the storage system. This section uses iPad as an example to describe how to log in to the DeviceManager. The login operations on other operating systems are similar.
  • (Applicable to V300R003C00/V300R003C10) For a 2 U controller enclosure (5300 V3/5500 V3), the default IP addresses of the management network ports on controllers A and B are respectively 192.168.128.101 and 192.168.128.102, and the default subnet mask is 255.255.255.0. For a 3 U or 6 U controller enclosure (5600 V3/5800 V3/6800 V3), the default IP addresses of the management network ports on management modules 0 and 1 are respectively 192.168.128.101 and 192.168.128.102, and the default subnet mask is 255.255.0.0.
  • (Applicable to V300R003C20) For a 2 U controller enclosure (5300 V3/5500 V3), the default IP addresses of the management network ports on controllers A and B are respectively 192.168.128.101 and 192.168.128.102, and the default subnet mask is 255.255.0.0. For a 3 U or 6 U controller enclosure (5600 V3/5800 V3/6800 V3), the default IP addresses of the management network ports on management modules 0 and 1 are respectively 192.168.128.101 and 192.168.128.102, and the default subnet mask is 255.255.0.0.
  • The default user name and password of the super administrator are admin and Admin@storage.
  • By default, DeviceManager allows 32 users to log in concurrently.
  • If a user does not perform any operations after logging in to the system for a period longer than the timeout limit (the limit is 30 minutes by default and modifiable), the system logs out automatically.
  • If an account is not used to log in to the system for a certain period of time (the period is 60 days by default and modifiable), it will be locked and can only be unlocked by the super administrator.

Procedure

  1. Connect the iPad to the Wi-Fi network.
    1. On the iPad desktop, choose Settings > WLAN.

      The system goes to the WLAN page.

    2. In the CHOOSE A NETWORK area, choose the Wi-Fi network.

      The Enter Password page is displayed.

    3. In the Password text box, enter the password.
    4. Click Join.

      The iPad is connected the Wi-Fi network.

  2. Log in to the DeviceManager.
    1. On the iPad desktop, tap Safari.
    2. Set Address to https://xxx.xxx.xxx.xxx:8088/ismpad/login.html and click Go.xxx.xxx.xxx.xxx is the IP address of management port on the storage system.

      The DeviceManager login page is displayed.

    3. Optional: Select a language from the Language check box.

      NOTE:

      DeviceManager supports two languages: simplified Chinese and English.

    4. In User Name and Password, enter the user name and password.

      NOTE:
      • The default user name and password are admin and Admin@storage.
      • If a verification code is required, enter the verification code.
      • If you forget the password as an administrator or a read-only user, contact the super administrator to reset the password. For details, see Modifying a User. If you forget the password as a super administrator (admin by default), contact root administrator _super_admin to log in to the CLI through a serial port and run initpasswd to reset the password.
      • Change the default login password immediately after you have logged in to the storage system for the first time. Periodically change your login password. For details about how to change the password, see Changing Password (Applicable to V300R003C00/V300R003C10)Changing Password (Applicable to V300R003C20).

    5. Click Login.

      The system enters the management page, where you can check the alarms, performance statistics, and the basic information of the storage system.