"Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions."
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
add hyper_metro_consistency_group pair

add hyper_metro_consistency_group pair

Function

The add hyper_metro_consistency_group pair command is used to add a HyperMetro pair to a HyperMetro consistency group.

Format

add hyper_metro_consistency_group pair consistency_group_id=? pair_id=?

Parameters

Parameter

Description

Value

pair_id=? ID of the HyperMetro pair.

Run the "show hyper_metro_pair general" command without parameters to obtain the value.

consistency_group_id=? ID of the HyperMetro consistency group.

Run the "show hyper_metro_consistency_group general" command without parameters to obtain the value.

Level

Administrator

Usage Guidelines

None

Example

To add HyperMetro pair 1 to HyperMetro consistency group 1, run the following command.

admin:/>add hyper_metro_consistency_group pair consistency_group_id=1 pair_id=1
CAUTION: You are about to add a pair to the HyperMetro consistency group. 
After the pair is added to the consistency group, the pair will use the consistency group's control policies. You cannot operate the pair in this consistency group. 
Suggestion: Before performing this operation, ensure that the parameters are correct to prevent service exceptions.
Do you wish to continue?(y/n)y
Command executed successfully.

System Response

None

Translation