No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Command Reference 10

OceanStor 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3 Storage System V300R003

"Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions."
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change service ndmp_config

change service ndmp_config

Function

The change service ndmp_config command is used to modify the NDMP configuration.

Format

change service ndmp_config { is_enabled=? | port=? | ip=? | restore_quota=? | support_snapshot=? | ignore_ctime=? } *

Parameters

Parameter

Description

Value

is_enabled=? Whether to enable the NDMP service.

The value can be "yes" or "no".

  • "yes": enables the NDMP service.
  • "no": disables the NDMP service.
port=? Port ID.

The value must be an integer from 10000 to 10099.

ip=? Listen IP address.

-

restore_quota=? Quota restored to the file system.

The value must be an integer from 0 to 100.

support_snapshot=? Whether to support snapshots. This parameter is valid in developer mode only. For details about how to log in to developer mode, see Restricted Command Reference.

The value can be "yes" or "no".

  • "yes": Snapshots are supported.
  • "no": Snapshots are not supported.
ignore_ctime=? Whether to ignore the ctime during backup.

The value can be "yes" or "no".

  • "yes": The ctime is ignored.
  • "no": The ctime is not ignored.

Level

Administrator

Usage Guidelines

None

Example

  • Modify the NDMP configuration.

    admin:/>change service ndmp_config port=10000 ip=192.168.0.1 restore_quota=95 ignore_ctime=no
    Command executed successfully.
  • Modify the NDMP configuration.

    admin:/>change service ndmp_config is_enabled=yes
    Command executed successfully.
  • Close the NDMP service.

    admin:/>change service ndmp_config is_enabled=no
    WARNING:You are about to disable the NDMP service. This operation causes the NDMP service provided by the storage device unavailable. 
    Suggestion: Before performing this operation, ensure that the NDMP service is no longer needed.
    Have you read warning message carefully?(y/n)y
     
    Are you sure you really want to perform the operation?(y/n)y
    Command executed successfully