Command Reference 10

OceanStor 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3 Storage System V300R003

"Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions."
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show bbu general

show bbu general

Function

The show bbu general command is used to query details on BBUs. Run this command if you need to query the ID, status, voltage, and voltage of the controller module where the BBU resides.

Format

show bbu general [ bbu_id=? ]

Parameters

Parameter

Description

Value

bbu_id=? ID of a BBU.

To obtain the value, run "show bbu general" without parameter.

Level

Guest

Usage Guidelines

None.

Example

  • Query details on all BBUs. The command output varies depending on a specific product.

    admin:/>show bbu general
     
    ID Health Status Running Status Current Voltage(V) Number of Discharges
    ------- ------------- -------------- ------------------ --------------------
    ENG0.A0 Normal Online 11.7 27
    ENG0.A1 Normal Online 11.7 7
    ENG0.B0 Normal Online 11.7 27
    ENG0.B1 Normal Online 11.7 7
  • Query details on the BBU whose ID is "ENG0.A0". The ID and output vary depending on a specific product.

    admin:/>show bbu general bbu_id=ENG0.A0
     
    ID : ENG0.A0
    Health Status : Normal
    Running Status : Online
    Current Voltage(V) : 11.7
    Number of Discharges : 27
    Firmware Version : 1.17T18
    Delivered On : 2012-4-29
    Owning Controller : 0A
    Electronic Label : [Board Properties]
    BoardType=STLZ01PWRA
    BarCode=210235G404Z0C5000218
    Item=0235G404
    Description=PANGEA,STLZ01PWRA,Battery Backup Unit
    Manufactured=2012-05-19
    VendorName=Huawei
    IssueNumber=00
    CLEICode=
    BOM=

System Response

The following table describes the parameter meanings.

Parameter

Meaning

ID

BBU ID.

Health Status

Health status of a BBU.

Running Status

Running status of a BBU.

Current Voltage(V)

Current voltage of the BBU (V).

Number Of Discharges

Times of BBU discharge.

Firmware Version

Firmware version of the BBU.

Delivered On

Delivery time of the BBU.

Owning Controller

Owning controller of the BBU.

Electronic Label

Electronic label of the BBU.