"Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions."
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show port fibre_module

show port fibre_module

Function

The show port fibre_module command is used to query details on all optical transceivers in the storage system.

Format

show port fibre_module

Parameters

None

Level

Guest

Usage Guidelines

Running the "show port fibre_module" command queries information about all optical modules.

Example

To query details on all optical transceivers in the storage system, run the following command. The command output varies depending on a specific product.

admin:/>show port fibre_module
 
  PortID      Health Status  Running Status  Type        
  ----------  -------------  --------------  ----------  
  ENG0.A1.P0  Normal         Link Down       Multi Mode  
  ENG0.A1.P1  Normal         Link Down       Multi Mode  
  ENG0.A1.P2  Normal         Link Down       Multi Mode  
  ENG0.A1.P3  Normal         Link Down       Multi Mode  
  ENG0.B1.P0  Normal         Link Down       Multi Mode  
  ENG0.B1.P1  Normal         Link Down       Multi Mode  
  ENG0.B1.P2  Normal         Link Down       Multi Mode  
  ENG0.B1.P3  Normal         Link Down       Multi Mode  
 
  Working Rate(Mbps)  Vendor           Model            SN
  ------------------  ---------------  ---------------  ---------------
  8000                AVAGO            AFBR-57D7APZ     AA1207AJ2KC
  8000                AVAGO            AFBR-57D7APZ     AA1207AJ2KE
  8000                AVAGO            AFBR-57D7APZ     AA1207AJ2JZ
  8000                AVAGO            AFBR-57D7APZ     AA1207AJ2JT
  8000                AVAGO            AFBR-57D7APZ     AD1209A0E51
  8000                AVAGO            AFBR-57D7APZ     AD1209A0E59
  8000                AVAGO            AFBR-57D7APZ     AD1209A0E54
  8000                AVAGO            AFBR-57D7APZ     AD1209A0E4K

System Response

The following table describes the parameter meanings.

Parameter

Meaning

PortID

Optical module ID.

Health Status

Health status.

Running Status

Operating status.

Type

Optical module type.

Working Rate(Mbps)

Maximum speed supported by the optical module.

Vendor

Vendor information.

Model

Model.

SN

SN.