Log Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document supports all the logs of device, including the parameters, meaning, possible causes and solution.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MFIB/4/REACH_TO_MAX

MFIB/4/REACH_TO_MAX

Message

MFIB/4/REACH_TO_MAX:Current route number [route-number] reached the route limit: [route-limit]. (Protocol=[STRING], Vpn=[STRING], FileLine=[STRING][STRING])

Description

The current routing entries reached the maximum value supported by the device.

Parameters

Parameter Name Parameter Meaning
[route-number] Number of routing entries.
[route-limit] Maximum number of routing entries supported by the device.
Protocol Indicates the flag of IPv4 or IPv6.
Vpn VPN name.
FileLine Name of the source code file and the line number of this log message.

Possible Causes

The current routing entries reached the maximum value supported by the device.

Procedure

  • If services are not affected, no action is required.
  • If services are affected and the routing entries belong to the public network, run the multicast forwarding-table route-limit limit command in the system view to increase the maximum number of routing entries that can be maintained in the multicast forwarding table. If the routing entries belong to a VPN, run the multicast forwarding-table route-limit limit command in the VPN instance view to increase the maximum number.
  • If increasing the maximum number is not allowed due to the processing capability limit of the system, Collect log information and configuration information, and then contact technical support personnel.