POE/6/PDPWROFF
Parameters
Parameter Name | Parameter Meaning |
---|---|
[STRING] | Indicates the name of the interface connected to the PD. |
Possible Causes
1.
The system time was within the power-off period.
2.
The PD was disconnected from the interface.
3.
The system power was insufficient.
4.
The PD was powered off manually.
Procedure
- The processing methods are as follows:
- If the system time was within the power-off period, this log message is informational only and no action is required.
- If the PD was disconnected from the interface, this log message is informational only and no action is required.
- If the system power was insufficient, remove the unneeded PDs.
- If the PD was powered off manually, this log message is informational only and no action is required.
If the log is not generated for the preceding reasons, contact Huawei technical support engineers.