No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document supports all the logs of device, including the parameters, meaning, possible causes and solution.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RIPNG/3/NO_GLO_SITE_ADDR_F

RIPNG/3/NO_GLO_SITE_ADDR_F

Message

RIPNG/3/NO_GLO_SITE_ADDR_F:Specific request is dropped, because global or site-local address is not assigned for interface [interface-name]. (ProcessId=[ULONG])

Description

The request of RIPng is dropped because there was no global or site-local address assigned for interface.

Parameters

Parameter Name Parameter Meaning
[interface-name] Indicates the interface name.
ProcessId Indicates the process ID.

Possible Causes

If an Update packet was sent to a non-RIPng interface, the global address or the local address was considered as the source address.

Procedure

  1. Configure a global address or a local address on the interface.
Translation
Download
Updated: 2019-05-29

Document ID: EDOC1000097209

Views: 83445

Downloads: 181

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next