Log Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document supports all the logs of device, including the parameters, meaning, possible causes and solution.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SOCKET/6/TCPCONNBLK

SOCKET/6/TCPCONNBLK

Message

SOCKET/6/TCPCONNBLK:The current TCP connection was blocked at [ULONG]:[ULONG]:[ULONG] (Hour:Minute:Second)

Description

The current TCP connection was blocked.

Parameters

Parameter Name Parameter Meaning
blocked at indicates the time when the TCP connection or disconnection is cut off. The format is HH:MM:SS.

Possible Causes

1. The user called the Close function to turn off the socket.

2. The TCP server received RST packets from the TCP client.

3. TCP retransmission timed out.

4. Failed to perform TCP keepalive detection.

Procedure

  1. This log message indicates a normal situation, and no action is required.