ERRDOWN/4/ERRDOWN_DOWNNOTIFY
Message
ERRDOWN/4/ERRDOWN_DOWNNOTIFY: Notify interface to change status to error-down. (InterfaceName=[STRING], Cause=[STRING])
Description
After an error-down event occurred on an interface, the log was displayed, indicating the interface name and the error down cause.
Parameters
Parameter Name | Parameter Meaning |
---|---|
InterfaceName | Interface name |
Cause | Cause of the errordown event |
Possible Causes
EFM detected a link fault, which can be a fault that occurred on the remote end or a threshold-crossing event.
The MSTP edge port received BPDU packets.
Procedure
- Check whether the interface is specified as an edge port.
-
Perform the following steps.
Run:
interfaceinterface-type interface-num
The interface view is displayed.
Run:
undo stp edged-port and undo shutdown
The edge port configuration is removed. Check whether the log still exists. If the log still exists, go to Step 4.
- Collect log information and configuration information, and then contact technical support personnel.