Log Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document supports all the logs of device, including the parameters, meaning, possible causes and solution.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RIP/6/GR_ABORT

RIP/6/GR_ABORT

Message

RIP/6/GR_ABORT: Aborted Graceful Restart. (AbortReason=[STRING], ProcessId=[ULONG])

Description

The GR process was aborted exceptionally.

Parameters

Parameter Name Parameter Meaning
AbortReason Indicates the cause of abort.
  • Virtual interface delete or Virtual interface went UP to Down event.
  • 1. An abort message wass received from the Helper because of the topology changed.
  • 2. An interface was added to the Restarter.
  • 3. The Restarter deleted existing interface.
  • 4. The status was changed.
  • 5. An event of deleting an interface or an event that interface status changes from Up to Down occurred.
ProcessId Indicates the process ID.

Possible Causes

The GR process was aborted exceptionally.

Procedure

  1. Services will be interrupted temporarily and then restored after the GR process is complete.