Log Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document supports all the logs of device, including the parameters, meaning, possible causes and solution.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
UPDATE/4/RETRY

UPDATE/4/RETRY

Message

UPDATE/4/RETRY(l): The memory was insufficient, and the update would be performed in one hour. (SyslogId=[syslog-id], User=[username], IP=[ip-address], Module=[module], Pre-UpdateVersion=[pre-update-version], UpdateVersion=[update-version], Status=[status], Duration(s)=[duration])

Description

The system failed to automatically update the signature database due to insufficient system memory, and the update module would try again in one hour.

Parameters

Parameter Name Parameter Meaning

syslog-id

Log ID

username

User name that is used to perform the update operation.

For scheduled update, SystemTimer is displayed for this parameter. If the system cannot obtain the user name, ** is displayed.

ip-address

IP address of the user that performs the update operation.

If the system cannot obtain the IP address, ** is displayed.

module

Update module, which can be:

  • IPS-SDB: IPS signature database
  • SA-SDB: SA signature database
  • CNC: malicious domain name database
pre-update-version

Version before the update

update-version

Version after the update

status

Update status, which can be:
  • apply: installation of the downloaded version

duration

Update duration, in seconds

Possible Causes

The system failed to automatically update the signature database due to insufficient system memory, and the update module would try again in one hour.

Procedure

  1. Wait for another automatic update or use commands to force an update.