Log Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document supports all the logs of device, including the parameters, meaning, possible causes and solution.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
INFO/5/FILTERINFOID_FAIL

INFO/5/FILTERINFOID_FAIL

Message

INFO/5/FILTERINFOID_FAIL:Failed to execute the info-center filter-id command. (Task=[STRING], Ip=[STRING], VpnName=[STRING], User=[STRING], Parameter="[STRING]")

Description

The info-center filter-id command failed to be executed.

Parameters

Parameter Name Parameter Meaning

Task

Task ID

Ip IP address
VpnName VPN instance name
User User name
Parameter IDs or mnemonics, separated by commas (,), which failed to be set

Possible Causes

The info-center filter-id command failed to be executed.

Procedure

  1. Check whether the log ID or mnemonic to be configured has been registered.

    • If the log ID or mnemonic has not been registered, register it.
    • If the log ID or mnemonic has been registered, go to Step 2.

  2. Check whether the log ID or mnemonic has been repeatedly configured.

    • If the log ID or mnemonic has been repeatedly configured, delete the repeated configuration.
    • If the log ID or mnemonic has not been repeatedly configured, go to Step 3.

  3. Check whether the log filtering configuration has reached the upper limit.

    • If the log filtering configuration has reached the upper limit, clear log filtering information.
    • If the log filtering configuration has not reached the upper limit, go to Step 4.

  4. Collect log information and configuration information, and then contact technical support personnel.