Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OSPF/4/TRAP_VIF_CFG_ERR

OSPF/4/TRAP_VIF_CFG_ERR

Message

OSPF/4/TRAP_VIF_CFG_ERR:Virtual interface configuration error has occurred. (ProcessId=[USHORT], RouterId=[IPADDR], Area=[IPADDR], Neighbor=[IPADDR], ErrorType=[ULONG], PacketType=[ULONG])

Description

The virtual interface was incorrectly configured.

Parameters

Parameter Name Parameter Meaning
Process ID Indicates the ID of an OSPF process.
RouterId Indicates the ID of a router.
Area Indicates the ID of an area.
Neighbor Indicates the IP address of a neighbor.
ErrorType Indicates the error type.
PacketType Indicates the packet type.

Possible Causes

The virtual interface was incorrectly configured.

Procedure

  1. Run the display ospf vlink command to check the authentication configuration of the virtual interface.