Log Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document supports all the logs of device, including the parameters, meaning, possible causes and solution.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CSPF/3/INVAL_LINK

CSPF/3/INVAL_LINK

Message

CSPF/3/INVAL_LINK: Received invalid link information from IGP [IgpName].

Description

Invalid link information was received from the IGP protocol.

Parameters

Parameter Name Parameter Meaning
[IgpName] Indicates the name of an IGP protocol, such as IS-IS and OSPF.

Possible Causes

Received link information is not valid.

Procedure

  1. Verify IGP database.

    • If IGP is OSPF use display ospf lsdb opaque-link and display ospf lsdb opaque-area command.

    • If IGP is ISIS use display isis traffic-eng link and display isis traffic-eng network command.

  2. Reset OSPF or IS-IS process.