Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document.
Note: Even the most advanced machine translation cannot match the quality of professional translators.
Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
L3VPN/4/ROUTE_MAX_EXCEEDED
Message
L3VPN/4/ROUTE_MAX_EXCEEDED:The total number of routes in VPN instance [vpn-instance] was [route-number], which exceeded the maximum value [maximum-value].
Parameters
Parameter Name | Parameter Meaning |
---|---|
[vpn-instance] | Indicates the name of the VPN instance. |
[route-number] | Indicates the number of the current routes. |
[maximum-value] | Indicates the maximum of the routes. |
Possible Causes
After the number of routes in the routing table reached the upper limit, new routes continued to be added.
Procedure
- Run the display ip routing-table vpn-instance [ vpn-instance-name ] statistics command to check the total number and types of routes in this VPN instance.
- Analyze the source of each route and check whether the number of current routes in the VPN instance meets the actual requirement.
- If so, go to Step 4.
- If not, go to Step 3.
- Delete unnecessary private routes, and then check whether the number of routes still reaches or exceeds the alarm threshold.
- If so, go to Step 5.
- If not, go to Step 6.
- Enter the VPN instance view and run the display this command to check the configuration of routing-table limit to check whether the set alarm threshold of private routes is proper.
- If so, go to Step 5.
- If not, run the routing-table limit number { alert-percent | simply-alert } command to re-configure a proper alarm threshold. Then, go to Step 6.
- Collect log information and configuration information, and then contact technical support personnel.
- End.