No relevant resource is found in the selected language.
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>
Your browser version is too early. Some functions of the website may be unavailable. To obtain better user experience, upgrade the browser to the latest version.
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document.
Note: Even the most advanced machine translation cannot match the quality of professional translators.
Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ISIS/6/ENABLE_TE_LV2_FAIL
ISIS/6/ENABLE_TE_LV2_FAIL
Message
ISIS/6/ENABLE_TE_LV2_FAIL:ISIS [process-id] failed to enable TE for Level-2.
Description
IS-IS failed to enable TE for the Level-2 interface.
Parameters
Parameter Name
Parameter Meaning
[process-id]
Indicates the ID of an IS-IS process.
Possible Causes
Failed to enable TE for the Level-2 interface.
Procedure
Run the display this command in a specified IS-IS process to check whether a NET is configured. If no NET is configured, configure a NET.
Run the traffic-eng command in a specified IS-IS process to re-enable TE.
Collect log information and configuration
information, and then contact technical support personnel.