PPP/4/LOOPBACK
PPP/4/LOOPBACK
Message
PPP/4/LOOPBACK:On the interface [interface-name],
PPP link was closed because loopback was detected after PPP link had
been established.
Description
The PPP link was closed because a loop was detected
after a link was established.
Parameters
Parameter Name
Parameter Meaning
[interface-name]
Indicates the local interface name.
Possible Causes
After a PPP link was established, a loop was detected
on the link.
Procedure
Check whether loopback detection is configured on the interface.
If loopback detection has been disabled and the link loop persists,
go to step 2.
Check whether a physical loop exists on the PPP link. Remove
the lines between the local device and the remote device. If the interface
goes Down, no loop exists on the local device. If the interface is
in Up status, contact technical support personnel.