Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwIsisIntfExtTable

hwIsisIntfExtTable

This table is used to obtain and set the values of the objects in hwIsisIntfExtTable associated with IS-IS.

The indexes of this table are hwIsisProcIdIndex, hwIsisInterfaceIndex, hwIsisIpTypeIndex, and hwIsisMTIdIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.24.2.1.22.1.1

hwIsisCircL1Cost

Integer32

Read-create

This object indicates the Level-1 link cost. The default value is 10. When the cost type is wide or wide-compatible, the value ranges from 1 to 16777215. If the cost type is not wide or wide-compatible, the value ranges from 1 to 63.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.24.2.1.22.1.2

hwIsisCircL2Cost

Integer32

Read-create

This object indicates the Level-2 link cost. The default value is 10. When the cost type is wide or wide-compatible, the value ranges from 1 to 16777215. If the cost type is not wide or wide-compatible, the value ranges from 1 to 63..

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.24.2.1.22.1.3

hwIsisL1TagValue

Unsigned32

Read-create

This object indicates the tag value of the Level-2 interface. The value ranges from 1 to 4294967295.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.24.2.1.22.1.4

hwIsisL2TagValue

Unsigned32

Read-create

This object indicates the tag value of the Level-2 interface. The value ranges from 1 to 4294967295.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.24.2.1.22.1.5

hwIsisCircSuppReachablity

INTEGER

Read-create

This object indicates that the interface address is suppressed from being advertised.
  • null(0): This function is not configured.
  • level1(1): The interface address is suppressed from being advertised in the Level-1 LSP.
  • level2(2): The interface address is suppressed from being advertised in the Level-2 LSP.
  • level2(3): The interface address is suppressed from being advertised in the Level-1 and Level-2 LSPs.

By default, the interface address is not suppressed from being advertised.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.24.2.1.22.1.6

hwIsisCircFrrBackup

INTEGER

Read-create

This object indicates that the interface is configured as a backup interface in Loop Free Alternate (LFA) calculation.
  • Null(0): The interface is not configured as a backup interface in LFA calculation.
  • level1(1): The interface in configured as a backup interface in Level-1 area.
  • level2(2): The interface in configured as a backup interface in Level-2 area.
  • level12(3): The interface in configured as a backup interface in Level-1 and Level-2 areas.

By default, an interface in configured as a backup interface in Level-1 and Level-2 areas.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.24.2.1.22.1.7

hwIsisCircMTRowStatus

RowStatus

Read-create

This object indicates the row status.
  • createAndGo(4): A row is created.
  • destroy(6): A row is deleted.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

The entries in this table can be created.

By configuring hwIsisCircMTRowStatus, you can create a topology instance but cannot create any IPv4 or IPv6 base topology.

Modification Restriction

The entries in this table can be modified.

When an IS-IS process is in the Disable state or the system is in the memory shortage, you cannot perform the Set operation on this table.

When the data of multiple entries is delivered in the same message block, if the data of one entry is incorrect, the data of the entire message block cannot be delivered to the IS-IS module.

Deletion Restriction

If the Destroy operation is performed, the other operations will not be handled.

Access Restriction

The entries in this table can be read without restriction.

Translation