MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntVe1PortConfigTable

hwEntVe1PortConfigTable

This table is used to configure and query VE1 port attributes and uses S/S/P as the index for this port.

The index of this table is hwEntVe1PortIndex.

The table entry of this table is hwEntVe1PortConfigEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.252.5.1.1

hwEntVe1PortIndex

Integer32

This object indicates the port index.

not-accessible

Current

1.3.6.1.4.1.2011.5.25.252.5.1.2

hwEntVe1PortFrameCheckMode

INTEGER

This object indicates whether to enable the CRC4 frame check.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: disable

Read-write

Current

1.3.6.1.4.1.2011.5.25.252.5.1.3

hwEntVe1PortImpedance

INTEGER

This object indicates the port impedance.

The options are as follows:

  • 1: ohm75
  • 2: ohm120

Default value: ohm75

Read-write

Current

1.3.6.1.4.1.2011.5.25.252.5.1.4

hwEntVe1PortSignalType

INTEGER

This object indicates the signaling type.

The options are as follows:

  • 1: ccs
  • 2: cas

Default value: ccs

Read-write

Current

1.3.6.1.4.1.2011.5.25.252.5.1.5

hwEntVe1PortAccessMode

INTEGER

This object indicates the digital access mode.

The options are as follows:

  • 1: digitalAccess
  • 2: directAccess

Default value: digitalAccess

Read-write

Current

1.3.6.1.4.1.2011.5.25.252.5.1.6

hwEntVe1PortL2Monitor

INTEGER

This object indicates whether to enable the Layer 2 error statistics function on the VE1 port.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: enable

Read-write

Current

1.3.6.1.4.1.2011.5.25.252.5.1.7

hwEntVe1PortErrAlarmSwitch

BITS

This object indicates the alarm switch.

bit0: PCM line fault

bit1: The bit error rate reaches the ULF threshold, the PCM is considered to be faulty and the port is forced to log out.

bit2: The bit error rate reaches the OLF threshold, the PCM is considered to be faulty and the port is forced to log out.

bit3: The bit error rate exceeds LDT threshold and the line is faulty instantaneously.

bit4: E1 clock slip reaches the PCM frame asynchronization threshold.

bit5: temporary event on a line.

Default value: 111000

NOTE:

If the bit value is 0, there is no alarm. If the bit value is 1, there is an alarm.

Read-write

Current

Creation Restriction

No entry can be created in this table.

Modification Restriction

None.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

None.