No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPbxGrpMemTable

hwEntPbxGrpMemTable

This table is used to configure and maintain members in a user group.

The indexes of this table are hwEntPbxGrpMemUsrGrpName, hwEntPbxGrpMemPbxuser, hwEntPbxGrpMemUnicallTel, hwEntPbxGrpMemFromDate, hwEntPbxGrpMemFromTime, hwEntPbxGrpMemToDate, hwEntPbxGrpMemToTime, hwEntPbxGrpMemRepeatMode, hwEntPbxGrpMemBeginDate, hwEntPbxGrpMemBeginWeekday, hwEntPbxGrpMemBeginTime, hwEntPbxGrpMemEndDate, hwEntPbxGrpMemEndWeekday, and hwEntPbxGrpMemEndTime.

The table entry of this table is hwEntPbxGrpMemEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.1

hwEntPbxGrpMemUsrGrpName

OCTET STRING

This object indicates a user group name.

Length: a string of 1 to 32 characters

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.2

hwEntPbxGrpMemPbxuser

OCTET STRING

This object indicates the member user name.

Length: a string of 1 to 32 characters

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.3

hwEntPbxGrpMemUnicallTel

OCTET STRING

This object indicates the ONLY number.

Length: a string of 1 to 44 digits

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.4

hwEntPbxGrpMemFromDate

OCTET STRING

This object indicates the start date.

Length: a string of 0 to 10 characters

Format: yyyy-mm-dd

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.5

hwEntPbxGrpMemFromTime

OCTET STRING

This object indicates the start time.

Length: a string of 0 to 8 characters

Format: hh:mm:ss

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.6

hwEntPbxGrpMemToDate

OCTET STRING

This object indicates the end date.

Length: a string of 0 to 10 characters

Format: yyyy-mm-dd

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.7

hwEntPbxGrpMemToTime

OCTET STRING

This object indicates the end time.

Length: a string of 0 to 8 characters

Format: hh:mm:ss

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.8

hwEntPbxGrpMemRepeatMode

INTEGER

This object indicates the repeat mode.

The options are as follows:

  • 1: noRepeat
  • 2: yearly
  • 3: monthly
  • 4: weekly
  • 5: daily

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.9

hwEntPbxGrpMemBeginDate

OCTET STRING

This object indicates the start date of the validity cycle.

Length: a string of 0 to 5 characters

Format: mm-dd

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.10

hwEntPbxGrpMemBeginWeekday

INTEGER

This object indicates the start weekday of the validity cycle.

The options are as follows:

  • 1: mon
  • 2: tue
  • 3: wed
  • 4: thu
  • 5: fri
  • 6: sat
  • 7: sun
  • 8: none

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.11

hwEntPbxGrpMemBeginTime

OCTET STRING

This object indicates the start time of the validity cycle.

Length: a string of 0 to 8 characters

Format: hh:mm:ss

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.12

hwEntPbxGrpMemEndDate

OCTET STRING

This object indicates the end date of the validity cycle.

Length: a string of 0 to 5 characters

Format: mm-dd

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.13

hwEntPbxGrpMemEndWeekday

INTEGER

This object indicates the end weekday of the validity cycle.

The options are as follows:

  • 1: mon
  • 2: tue
  • 3: wed
  • 4: thu
  • 5: fri
  • 6: sat
  • 7: sun
  • 8: none

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.14

hwEntPbxGrpMemEndTime

OCTET STRING

This object indicates the end time of the validity cycle.

Length: a string of 0 to 8 characters

Format: hh:mm:ss

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.15

hwEntPbxGrpMemRowStatus

RowStatus

This object indicates the row status.

The options are as follows:

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy
NOTE:

At present, only createAndGo and destroy are supported.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.16

hwEntPbxGrpMemAdminState

INTEGER

This object indicates the member service status.

The options are as follows:

  • 1: offline
  • 2: online

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.20.1.17

hwEntPbxGrpMemIndex

Integer32

This object indicates the member index.

Value range: 0 to 65535

read-create

current

Creation Restriction

An ONLY number is used only for registering users in the ONLY group. The ONLY number is in the global number format.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

None.

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 112408

Downloads: 677

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next