MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwCtStatisticsTable

hwCtStatisticsTable

hwCtStatisticsTable describes performance statistics of the TE tunnel interface configuration.

The index of this table is hwCtStatisticsIfIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.151.1.8.1.3

hwCtStatisticsCt0OutByteRate

Counter64

Read-only

It counts the rate in bytes/sec out from the CT0 of the TE tunnel interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.151.1.8.1.4

hwCtStatisticsCt0OutPktRate

Counter64

Read-only

It counts the rate in packets/sec out from the CT0 of the TE tunnel interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.151.1.8.1.5

hwCtStatisticsCt0OutPkt

Counter64

Read-only

It counts the out packets from the CT0 of the TE tunnel interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.151.1.8.1.6

hwCtStatisticsCt0OutPktByte

Counter64

Read-only

It counts the out bytes from the CT0 of the TE tunnel interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.151.1.8.1.7

hwCtStatisticsCt0OutErrorPkt

Counter64

Read-only

It counts the error packets from the CT0 of the TE tunnel interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.151.1.8.1.9

hwCtStatisticsCt1OutPktRate

Counter64

Read-only

It counts the rate in packets/sec out from the CT0 of the TE tunnel interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.151.1.8.1.13

hwCtStatisticsCt2OutByteRate

Counter64

Read-only

It counts the rate in bytes/sec out from the CT2 of the TE tunnel interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.151.1.8.1.14

hwCtStatisticsCt2OutPktRate

Counter64

Read-only

It counts the rate in packets/sec out from the CT2 of the TE tunnel interface.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

The entries in this table cannot be created.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction