No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
mplsFecTable

mplsFecTable

This table represents the FEC (Forwarding Equivalence Class) information associated with an LSP.

The index of this table is mplsFecIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.2.1.10.166.4.1.3.8.3.1.1

mplsFecIndex

IndexInteger

Not-accessible

The index which uniquely identifies this entry.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.166.4.1.3.8.3.1.2

mplsFecType

INTEGER {prefix(1),hostAddress(2)}

Read-create

The type of the FEC. If the value of this object is 'prefix(1)' then the FEC type described by this row is an address prefix.

If the value of this object is 'hostAddress(2)' then the FEC type described by this row is a host address." REFERENCE " RFC3036, Section 3.4.1. FEC TLV.

Currently, the maximum access is read-only.

1.3.6.1.2.1.10.166.4.1.3.8.3.1.3

mplsFecAddrPrefixLength

InetAddressPrefixLength

Read-create

If the value of the 'mplsFecType' is 'hostAddress(2)' then this object is undefined.

If the value of 'mplsFecType' is 'prefix(1)' then the value of this object is the length in bits of the address prefix represented by 'mplsFecAddr', or zero. If the value of this object is zero, this indicates that the prefix matches all addresses.

In this case the address prefix MUST also be zero (that is, 'mplsFecAddr' should have the value of zero.)

Currently, the maximum access is read-only.

1.3.6.1.2.1.10.166.4.1.3.8.3.1.4

mplsFecAddrType

InetAddressType

Read-create

The value of this object is the type of the Internet address. The value of this object, decides how the value of the mplsFecAddr object is interpreted.

Currently, the maximum access is read-only.

1.3.6.1.2.1.10.166.4.1.3.8.3.1.5

mplsFecAddr

InetAddress

Read-create

The value of this object is interpreted based on the value of the 'mplsFecAddrType' object.

This address is then further interpretted as a being used with the address prefix, or as the host address. This further interpretation is indicated by the 'mplsFecType' object. In other words, the FEC element is populated according to the Prefix FEC Element value encoding, or the Host Address FEC Element encoding.

Currently, the maximum access is read-only.

1.3.6.1.2.1.10.166.4.1.3.8.3.1.6

mplsFecStorageType

StorageType

Read-create

The storage type for this conceptual row.

Currently, the maximum access is read-only.

1.3.6.1.2.1.10.166.4.1.3.8.3.1.7

mplsFecRowStatus

RowStatus

Read-create

The status of this conceptual row. If the value of this object is 'active(1)', then none of the writable objects of this entry can be modified, except to set this object to 'destroy(6)'.

NOTE: if this row is being referenced by any entry in the mplsLdpLspFecTable, then a request to destroy this row, will result in an inconsistentValue error.

Currently, the maximum access is read-only.

Creation Restriction

The entries in this table cannot be created.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The LDP LSP must be set up on this device for an enter FEC.

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 126077

Downloads: 688

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next