No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
rcMplsTETunnelCfgTable

rcMplsTETunnelCfgTable

rcMplsTETunnelCfgTable is used to create an MPLS TE tunnel.

The index of this table is rcMplsTETunnelCfgTunnelID.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.65000.1.1.1.1

rcMplsTETunnelCfgTunnelID

Unsigned32

Not-accessible

This object indicates the ID of a tunnel.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.65000.1.1.1.2

rcMplsTETunnelCfgEgressLSRId

IpAddress

Read-create

This object indicates a tunnel destination IP address. If the value is set to 0.0.0.0, no tunnel destination IP address is configured, or a tunnel destination IP address is deleted.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.65000.1.1.1.3

rcMplsTETunnelCfgSetupPrio

Integer32

Read-create

The value of this object identifies a setup priority value. The value ranges from 0 to 7.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.65000.1.1.1.4

rcMplsTETunnelCfgHoldingPrio

Integer32

Read-create

The value of this object identifies a holding priority value. The value ranges from 0 to 7.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.65000.1.1.1.5

rcMplsTETunnelCfgRecordRoute

INTEGER{false(0),true(1)}

Read-create

The value of this object identifies whether the route record function is enabled:

  • 0: disabled

  • 1: enabled

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.65000.1.1.1.6

rcMplsTETunnelCfgBandwidth

Unsigned32

Read-create

The value of this object identifies the bandwidth to be reserved for a tunnel. The value ranges from 1 to 4000000000, in kbit/s.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.65000.1.1.1.7

rcMplsTETunnelCfgExplicitPathName

DisplayString

Read-create

This object indicates the name of an explicit path. If an empty string is used, no explicit path is used to establish a tunnel.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.65000.1.1.1.9

rcMplsTETunnelCfgHSB

INTEGER {false(0),true(1)}

Read-create

This object indicates whether hot standby is enabled:

  • 0: disabled

  • 1: enabled

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.65000.1.1.1.10

rcMplsTETunnelCfgHSBExplicitPathName

DisplayString

Read-create

This object indicates the name of an explicit path over which a hot-standby tunnel is established. If an empty string is used, no explicit path is used to establish a hot-standby tunnel.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.65000.1.1.1.12

rcMplsTETunnelCfgRowSta

RowStatus

Read-create

This object is used to create, modify, or delete a row in this table.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

An entry in this table can only be created after MPLS TE is enabled on a device.

Before you create rcMplsTETunnelCfgExplicitPathName and rcMplsTETunnelCfgHSBExplicitPathName entries in this table, use rcMplsTEExplicitPathNameCfgTable to create an MPLS TE explicit path.

Modification Restriction

Before you modify the rcMplsTETunnelCfgExplicitPathName and rcMplsTETunnelCfgHSBExplicitPathName entries, the changed value must be equal to the rcMplsTEExplicitPathNameCfgName value in rcMplsTEExplicitPathNameCfgTable.

Before you create the rcMplsTETunnelCfgHoldingPrio entry, ensure that the rcMplsTETunnelCfgSetupPrio entry is also created and set to a value greater than or equal to the rcMplsTETunnelCfgHoldingPrio value.

Before the rcMplsTETunnelCfgRecordRoute entry is set to 0, the rcMplsTETunnelCfgHSB object must be changed to 0. If the rcMplsTETunnelCfgHSB value is 1, the device automatically sets the rcMplsTETunnelCfgRecordRoute entry to 1.

Deletion Restriction

None.

Access Restriction

None.

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 122241

Downloads: 683

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next