MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPbxCrbtFileTable

hwEntPbxCrbtFileTable

This table is used to configure and maintain RBT files.

The index of this table is hwEntPbxCrbtFileName.

The table entry of this table is hwEntPbxCrbtFileEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.313.23.1.1

hwEntPbxCrbtFileName

INTEGER

This object indicates the name of an RBT file.

Length: a string of 1 to 64 characters

not-accessible

current

1.3.6.1.4.1.2011.5.25.313.23.1.2

hwEntPbxCrbtFileRowStatus

RowStatus

This object indicates the row status.

The options are as follows:

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy
NOTE:

At present, only createAndGo and destroy are supported.

read-create

current

1.3.6.1.4.1.2011.5.25.313.23.1.3

hwEntPbxCrbtFileDesc

OCTET STRING

This object indicates the RBT file description.

Length: a string of 1 to 64 characters

read-create

current

1.3.6.1.4.1.2011.5.25.313.23.1.4

hwEntPbxCrbtType

INTEGER

This object indicates the RBT type.

  • 1: enterpriserCrbt
  • 2: personalCrbt

read-create

current

1.3.6.1.4.1.2011.5.25.313.23.1.5

hwEntPbxCrbtFileCheckStatus

INTEGER

This object indicates the approval status of an RBT file.

The options are as follows:

  • 1: noCheck
  • 2: pass
  • 3: noPass

read-create

current

1.3.6.1.4.1.2011.5.25.313.23.1.6

hwEntPbxCrbtFileStorage

INTEGER

This object indicates the location where RBT files are stored.

The options are as follows:

  • 1: local
  • 2: mrs

Default value: local

read-create

current

1.3.6.1.4.1.2011.5.25.313.23.1.7

hwEntPbxCrbtFileEnterpriseName

OCTET STRING

This object indicates the name of the enterprise to which the RBT file belongs.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.4.1.2011.5.25.313.23.1.8

hwEntPbxCrbtFileUserName

OCTET

This object indicates the name of the user to which the RBT file belongs.

Length: a string of 1 to 32 characters

read-create

current

Creation Restriction

To create an entry, set a value for hwEntPbxCrbtType. hwEntPbxCrbtFileEnterpriseName must be configured for enterprise RBT and hwEntPbxCrbtFileUserName must be configured for personal RBT.

Modification Restriction

If hwEntPbxCrbtType is set to enterpriserCrbt, hwEntPbxCrbtFileEnterpriseName must be configured. If hwEntPbxCrbtType is set to personalCrbt, hwEntPbxCrbtFileUserName must be configured.

Deletion Restriction

None.

Access Restriction

None.

Translation