No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwDomainTable

hwDomainTable

The hwDomainTable is a domain information table. You can use this table to configure basic attributes of a domain. The AR provides two default domains, namely, default and default_admin. The default domains can be modified but cannot be deleted.

The index of this table is hwDomainName.

OID

Object

Syntax

Access

Description

Status

1.3.6.1.4.1.2011.5.2.1.4.1.1

hwDomainName

DisplayString

Read-only

This object indicates the domain name. The value is a string of 1 to 64 characters. The character string is case insensitive. The value cannot contain * ? ".

Current

1.3.6.1.4.1.2011.5.2.1.4.1.2

hwDomainAuthenSchemeName

DisplayString

Read-create

This object indicates the name of the authentication scheme used by the domain. The value is a string of 1 to 32 characters. The default authentication scheme of domains is default.

Current

1.3.6.1.4.1.2011.5.2.1.4.1.3

hwDomainAcctSchemeName

DisplayString

Read-create

This object indicates the name of the accounting scheme used by the domain. The value is a string of 1 to 32 characters. The default accounting scheme of domains is default.

Current

1.3.6.1.4.1.2011.5.2.1.4.1.4

hwDomainRadiusGroupName

DisplayString

Read-create

This object indicates the name of the RADIUS server group used by the domain. The value is a string of 1 to 32 characters. The RADIUS group must already exist.

Current

1.3.6.1.4.1.2011.5.2.1.4.1.11

hwDomainRowStatus

RowStatus

Read-create

This object indicates the domain status.

Current

1.3.6.1.4.1.2011.5.2.1.4.1.13

hwDomainServiceSchemeName

DisplayString

Read-create

This object indicates the name of the service scheme used by the domain. The value is a string of 1 to 32 characters. The service scheme must already exist.

Current

Creation Restriction

None.

Modification Restriction

The modification restrictions are as follows:

  • The authentication scheme specified for a domain must exist; otherwise, the configuration fails.

  • The accounting scheme specified for a domain must exist; otherwise, the configuration fails.

  • The RADIUS server template specified for authentication and accounting in a domain must exist; otherwise, the configuration fails.

  • The service scheme specified for a domain must exist; otherwise, the configuration fails.

Deletion Restriction

A domain cannot be deleted in the following situations:

  • The domain contains users.

  • Indicates the domain referenced by WLAN-ESS and WLAN-BSS.

  • The domain is a default domain.

Access Restriction

None.

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 121535

Downloads: 681

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next