MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntVe1PortL1AlarmThresholdTable

hwEntVe1PortL1AlarmThresholdTable

This table is used to set the Layer 1 port degradation alarm threshold for the VE1 port.

The index of this table is hwEntVe1PortL1AlarmThresholdIndex.

The table entry of this table is hwEntVe1PortL1AlarmThresholdEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.252.7.1.1

hwEntVe1PortL1AlarmThresholdIndex

Integer32

This object indicates the port index.

Not-accessible

Current

1.3.6.1.4.1.2011.5.25.252.7.1.2

hwEntVe1PortDmAlarmThreshold

Integer32

This object indicates the degrading minute alarm threshold.

Value range: 0 to 60

Default value: 8

NOTE:

This object is configurable when the CRC4 function is enabled.

Read-write

Current

1.3.6.1.4.1.2011.5.25.252.7.1.3

hwEntVe1PortEsAlarmThreshold

Integer32

This object indicates the error code second alarm threshold.

Value range: 0 to 3600

Default value: 432

NOTE:

This object is configurable when the CRC4 function is enabled.

Read-write

Current

1.3.6.1.4.1.2011.5.25.252.7.1.4

hwEntVe1PortCsesAlarmThreshold

Integer32

This object indicates the alarm threshold for serious continuous error code seconds.

Value range: 0 to 60

Default value: 4

NOTE:

This object is configurable when the CRC4 function is enabled.

Read-write

Current

Creation Restriction

No entry can be created in this table.

Modification Restriction

None.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

None.