Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntCallerEmulateTable

hwEntCallerEmulateTable

This table is used to configure and query the calling party emulation test.

A user can use the NMS to deliver a calling party emulation test command to the host. The emulation port automatically enters the off-hook state and dials the specified called number, which can be any available numbers on the live network. Based on loopback processing, the user can speak or press keys to verify that the call line is normal after the calling party picks up the phone.

The index of this table is hwEntCallerEmulatePort.

The table entry of this table is hwEntCallerEmulateEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.314.5.1.1

hwEntCallerEmulatePort

Integer32

This object indicates the calling party emulation test port.

bits 31-24: reserved

bits 23-16: slot index

bits 15-8: subcard index

bits 7-0: port index

Not-accessible

Current

1.3.6.1.4.1.2011.5.25.314.5.1.2

hwEntCallerEmulateOprType

INTEGER

This object indicates the operation type of the calling party emulation test.

The options are as follows:

  • 1: stop
  • 2: start

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.5.1.3

hwEntCallerEmulateTelno

OCTET STRING

This object indicates the called number in the calling party emulation test.

Length: a string of 1 to 32 characters

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.5.1.4

hwEntCallerEmulateStatus

Integer32

This object indicates the calling party emulation test status.

Value range: 19 to 21

  • 19: off-hook
  • 20: playing the dial tone
  • 21: dialing completed

Read-only

Current

Creation Restriction

Currently, only one channel of the calling party emulation test is supported.

Modification Restriction

None.

Deletion Restriction

Users can stop the test and delete test configuration data.

Access Restriction

None.