No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntSysParaConfigTable

hwEntSysParaConfigTable

This table is used to configure and query system parameters.

This table does not have any indexes.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.249.1.1

hwEntSysParaCountry

INTEGER

This object indicates the region where the AR is used.

The options are as follows:

  • 1: chinaMainland
  • 2: chinaHongkong
  • 3: brazil
  • 4: egypt
  • 5: singapore
  • 6: thailand
  • 7: france
  • 8: britainMsfuk
  • 9: britainEtsi
  • 10: bulgaria

Default value: chinaMainland

Read-write

Current

1.3.6.1.4.1.2011.5.25.249.1.2

hwEntSysParaStopInitialRing

INTEGER

This object indicates whether to stop the initial ring.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: enable

Read-write

Current

1.3.6.1.4.1.2011.5.25.249.1.3

hwEntSysParaMwiMode

INTEGER

This object indicates the message waiting indicator (WMI) mode.

The options are as follows:

  • 1: highVoltage
  • l: fskWithRing
  • 3: fskWithoutRing

Default value: fskWithRing

read-write

current

1.3.6.1.4.1.2011.5.25.249.1.4

hwEntSysParaFlashHookUpper

Integer32

This object indicates the upper limit of the hookflash duration.

Value range: 50 to 1400

Default value: 350

Unit: millisecond

Read-write

Current

1.3.6.1.4.1.2011.5.25.249.1.5

hwEntSysParaFlashHookLower

Integer32

This object indicates the lower limit of the hookflash duration.

Value range: 50 to 1400

Default value: 100

Unit: millisecond

Read-write

Current

1.3.6.1.4.1.2011.5.25.249.1.6

hwEntSysParaParkFeed

INTEGER

This object indicates whether to enable current restriction for a locked user port.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: disable

Read-write

Current

1.3.6.1.4.1.2011.5.25.249.1.7

hwEntSysParaPcm

INTEGER

This object indicates the A/U rate of the PCM.

The options are as follows:

  • 1: aLaw
  • 2: uLaw

Default value: aLaw

Read-write

Current

1.3.6.1.4.1.2011.5.25.249.1.8

hwEntSysParaRingFrequency

INTEGER

This object indicates the ring flow frequency.

The options are as follows:

  • 1: frequency16HZ
  • 2: frequency25HZ
  • 3: frequency50HZ

Default value: frequency25HZ

Read-write

Current

1.3.6.1.4.1.2011.5.25.249.1.9

hwEntSysParaRingAcAmplitude

INTEGER

This object indicates the AC amplitude of the ring flow.

The options are as follows:

  • 1: ac65Vrms
  • 2: ac50Vrms

Default value: ac50Vrms

NOTE:

This object is not supported temporarily.

read-write

current

1.3.6.1.4.1.2011.5.25.249.1.10

hwEntSysParaGlobalDigitmap

INTEGER

This object indicates whether to enable the global digit map.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: enable

Read-write

Current

1.3.6.1.4.1.2011.5.25.249.1.11

hwEntSysParaSctpSendChecksum

INTEGER

This object indicates whether to enable the SCTP send check.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: enable

Read-write

Current

1.3.6.1.4.1.2011.5.25.249.1.12

hwEntSysParaSctpReceiveChecksum

INTEGER

This object indicates whether to enable the SCTP receive check.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: enable

Read-write

Current

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table can be modified without restriction.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 94248

Downloads: 648

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share