MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwRecordSchemeTable

hwRecordSchemeTable

hwRecordSchemeTable is a table of a recording scheme, including the recording scheme name and a TAC template name. You can add, delete, modify, or query the recording scheme.

The index of this table is hwRecordSchemeName.

OID

Object Name

Access

Maximum Access

Description

Status

1.3.6.1.4.1.2011.5.2.1.30.1.1

hwRecordSchemeName

Read-only

DisplayString

This object specifies the name of the recording scheme.

Current

1.3.6.1.4.1.2011.5.2.1.30.1.2

hwRecordTacGroupName

Read-create

DisplayString

This object indicates the name of the HWTACACS server template referenced in the recording scheme. The value is a string of 1 to 32 characters. The HWTACACS server template must have been created.

Current

1.3.6.1.4.1.2011.5.2.1.30.1.3

hwRecordRowStatus

Read-create

RowStatus

This object indicates the recording scheme status.

Current

Creation Restriction

hwRecordSchemeName cannot be created.

Modification Restriction

  • hwRecordSchemeName cannot be modified.
  • hwRecordRowStatus can be created and deleted but cannot be modified.

Deletion Restriction

The recording schemes in use cannot be deleted. To delete a recording scheme in use, cancel the reference relationship of the scheme first.

Access Restriction

None.