MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwIsisIntfBfdTable

hwIsisIntfBfdTable

This table is used to obtain and set the values of the objects in hwIsisIntfBfdTable associated with IS-IS.

The indexes of this table are hwIsisProcIdIndex, hwIsisInterfaceIndex, and hwIsisIpTypeIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.24.2.1.23.1.1

hwIsisCircBfdState

INTEGER

Read-create

The value of this object identifies the BFD status:
  • enable(1): enables BFD.
  • disable(2): disables BFD.
  • static(3): configures static BFD.
  • block(4): blocks BFD on an interface.
By default, BFD is not enabled.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.24.2.1.23.1.2

hwIsisCircBfdMinTxInterval

Integer32

Read-create

The value of this object identifies the minimum interval for sending BFD packets. The value range and default value of this object are determined by the license file.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.24.2.1.23.1.3

hwIsisCircBfdMinRxInterval

Integer32

Read-create

The value of this object identifies the minimum interval for sending BFD packets. The value range and default value of this object are determined by the license file.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.24.2.1.23.1.4

hwIsisCircBfdMultiplier

Integer32

Read-create

The value of this object identifies the local BFD detection multiplier. The value range and default value of this object are determined by the license file.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.24.2.1.23.1.5

hwIsisCircBfdFrrBinding

Enumeration

Read-create

This object indicates that the BFD status is bound to IS-IS Auto FRR.
  • enable(1): indicates that BFD is bound to IS-IS Auto FRR.
  • disable(2): indicates that BFD is not bound to IS-IS Auto FRR.
By default, the BFD session status is not bound to IS-IS Auto FRR.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

No entry can be created in this table.

Modification Restriction

When an IS-IS process is in the Disable state or the system is in the memory shortage, you cannot perform the Set operation on this table.

When the data of multiple entries is delivered in the same message block, if the data of one entry is incorrect, the data of the entire message block cannot be delivered to the IS-IS module.

The get, getnext, or set operation cannot be performed on the interface (at present, only including the loopback interface) that does not support BFD. When the hwIsisCircBfdState object is set to disable(2), it indicates that BFD configurations are canceled. Although the values of both hwIsisCircBfdMinRxInterval and hwIsisCircBfdMinTxInterval range from 1 to 65535, the valid range is determined by the license file.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.

Translation