No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
mplsXCDown

mplsXCDown

OID

Object

Bound variable

Description

Implemented Specifications

1.3.6.1.2.1.10.166.2.0.2

mplsXCDown

mplsXCOperStatus, -- start of range

mplsXCOperStatus -- end of range

This notification is generated when the mplsXCOperStatus object for one or more contiguous entries in mplsXCTable are about to enter the down(2) state from some other state. The included values of mplsXCOperStatus MUST both be set equal to this down(2) state.

The two instances of mplsXCOperStatus in this notification indicate the range of indexes that are affected. Note that all the indexes of the two ends of the range can be derived from the instance identifiers of these two objects. For cases where a contiguous range of cross-connects have transitioned into the down(2) state at roughly the same time, the device SHOULD issue a single notification for each range of contiguous indexes in an effort to minimize the emission of a large number of notifications.

If a notification has to be issued for just a single cross-connect entry, the instance identifier (and values) of the two mplsXCOperStatus objects must be identical.

This object is implemented as defined in the corresponding MIB files.

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 94029

Downloads: 648

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next