No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntityStateTable

hwEntityStateTable

This table describes the status of the entity such as the status of management, operation, backup, alarm, CPU usage and high threshold, and memory usage and high threshold.

The index of this table is entPhysicalIndex.

OID

Object Name

Syntax

Description

Max Access

Implemented Specifications

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.1

hwEntityAdminStatus

Integer

Management status of the entity. The values are as follows:

  • 1: notSupported: indicates that the entity is unavailable.
  • 2: locked: indicates that the entity is locked.
  • 3: shuttingDown: indicates that the entity is shut down.
  • 4: unlocked: indicates that the entity is available.

Default value: 4.

Read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

Integer

Operating status of the entity. The values are as follows:

  • 1: notSupported: indicates that the entity is unavailable.
  • 2: disabled: indicates that the entity is disabled.
  • 3: enabled: indicates that the entity is enabled.
  • 4: offline: indicates that the entity is not used.
  • 15: protocollUp: indicates that the protocol status of the entity is in Up state.
  • 16: linkUp: indicates that the entity status is in Up state.
  • 17: linkDown: indicates that the entity status is in Down state.

Default value: 3.

Read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.3

hwEntityStandbyStatus

Integer

Backup status of the entity. The values are as follows:

  • 1: notSupported: indicates that the entity does not support backup.
  • 2: hotStandby: indicates the hot backup.
  • 3: coldStandby: indicates the cold backup.
  • 4: providingService: indicates the active status.

Default value: 1.

Read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.5

hwEntityCpuUsage

Integer

Real-time CPU usage of the entity.

Value range: 0-100.

Default value: 0.

Read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.6

hwEntityCpuUsageThreshold

Integer

High threshold of the CPU usage of the entity.

Value range: 2-100.

Default value: 80.

Read-write

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.7

hwEntityMemUsage

Integer

Memory usage of the entity.

Value range: 0-100.

Default value: 0.

Read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.8

hwEntityMemUsageThreshold

Integer

Threshold of the memory usage of the entity.

Value range: 75-100.

Read-write

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.9

hwEntityMemSize

Integer

System memory capacity. If there are LPUs, total physical memory capacity of LPUs is displayed, in bytes.

Read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.10

hwEntityUpTime

Integer

Time to start the entity, in seconds.

Read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.11

hwEntityTemperature

Integer

Entity temperature, in °C.

Read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.12

hwEntityTemperatureThreshold

Integer

High threshold of the entity temperature, in °C.

Read-write

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.13

hwEntityVoltage

Integer

Voltage of the entity, in V.

Read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.14

hwEntityVoltageLowThreshold

Integer

Low threshold of the entity voltage, in V.

Read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.15

hwEntityVoltageHighThreshold

Integer

High threshold of the entity voltage, in V.

Read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.16

hwEntityTemperatureLowThreshold

Integer

Low temperature threshold of the entity, in °C.

Read-write

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.19

hwEntityMemSizeMega

Integer

Total physical memory capacity, in megabytes.

read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.37

hwEntityMemUsed

Unsigned32

Memory used by the entity, in bytes.

read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.43

hwEntityBoardName

OCTET STRING

Name of a specified board.

read-only

This object is used only to obtain information about the main control board and interface board.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.44

hwEntityBoardDescription

OCTET STRING

Description of specified board.

read-only

This object is used only to obtain information about the main control board and interface board.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.45

hwEntity5MinCpuUsage

Integer

CPU usage of the entity within the latest 5 minutes.

Value range: 0-100.

Default value: 0.

read-only

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

No entry can be created in this table.

Modification Restriction

Only the entries in hwEntityCpuUsageThreshold [6], hwEntityMemUsageThreshold [8], hwEntityTemperatureThreshold [12], and hwEntityTemperatureLowThreshold [16] can be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

None