MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwIpv6Tunnel4Over6CfgTable

hwIpv6Tunnel4Over6CfgTable

This table is the parameter configuration table for the IPv4 over IPv6 tunnel. It contains configurations of the IPv4 over IPv6 tunnel interface on a device.

The index of this table is ipv6IfIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.201.1.2.1.1

hwIpv6TunnelEncapLimit

Integer32(0..255)

Read-write

The value of this object identifies the encapsulation limit value of a tunnel.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.201.1.2.1.2

hwIpv6TunnelEncapLimitDisable

TruthValue

Read-only

This object indicates whether the encapsulation limit of the tunnel is enabled.

By default, it is disable.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.201.1.2.1.3

hwIpv6TunnelFlowLabel

Integer32(0..1048575)

Read-write

The value of this object identifies the value of the flow label used by a tunnel.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.201.1.2.1.4

hwIpv6TunnelHopLimit

Integer32(1..255)

Read-write

The value of this object identifies the the limit number of hops of a tunnel.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.201.1.2.1.5

hwIpv6TunnelTrafficClass

Integer32(0..255)

Read-write

The value of this object identifies the values of traffic classes of a tunnel.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.201.1.2.1.6

hwIpv6TunnelTrafficOriginal

TruthValue

Read-write

This object indicates whether to use the original traffic of received packets.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.201.1.2.1.7

hwIPv6Tunnel4Over6CfgUndoFlag

INTEGER { undoTunnelEncapLimit(1), undoTunnelFlowLabel(2), undoTunnelHopLimit(3), undoTunnelTrafficClass(4), invalid(5) }

Read-write

This object indicates canceling of configurations of the IPv4 over IPv6 tunnel parameters.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

You can create entries in this table.

Before creating this table, the hwTunnelCfgTable table should be created first.

Modification Restriction

All objects except hwIpv6TunnelEncapLimitDisable can be modified.

The hwIPv6Tunnel4Over6CfgUndoFlag object and the other objects are mutually exclusive, and cannot be delivered at the same time. If they are delivered at the same time, only the hwIPv6Tunnel4Over6CfgUndoFlag object can be successfully delivered.