Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
frCircuitTable

frCircuitTable

This table contains information about specific Data Link Connections (DLC) or virtual circuits.

The indexes of this table are frCircuitIfIndex and frCircuitDlci.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.2.1.10.32.2.1.1

frCircuitIfIndex

InterfaceIndex

Read-only

The ifIndex Value of the ifEntry this virtual circuit is layered onto.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.32.2.1.2

frCircuitDlci

DLCI

Read-only

The Data Link Connection Identifier for this virtual circuit.

In Huawei, values 16 to 1022 are implemented.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.32.2.1.3

frCircuitState

INTEGER

{

invalid (1),

active (2),

inactive (3)

}

Read-create

Indicates whether the particular virtual circuit is operational. In the absence of a Data Link Connection Management Interface, virtual circuit entries (rows) may be created by setting virtual circuit state to 'active', or deleted by changing Circuit state to 'invalid'. Whether or not the row actually disappears is left to the implementation, so this object may actually read as 'invalid' for some arbitrary length of time. It is also legal to set the state of a virtual circuit to 'inactive' to temporarily disable a given circuit.

Currently, the maximum access is Read-only.

1.3.6.1.2.1.10.32.2.1.4

frCircuitReceivedFECNs

Counter32

Read-only

Number of frames received from the network indicating forward congestion since the virtual circuit was created.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.32.2.1.5

frCircuitReceivedBECNs

Counter32

Read-only

Number of frames received from the network indicating backward congestion since the virtual circuit was created.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.32.2.1.6

frCircuitSentFrames

Counter32

Read-only

The number of frames sent from this virtual circuit since it was created.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.32.2.1.7

frCircuitSentOctets

Counter32

Read-only

The number of octets sent from this virtual circuit since it was created.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.32.2.1.8

frCircuitReceivedFrames

Counter32

Read-only

Number of frames received over this virtual circuit since it was created.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.32.2.1.9

frCircuitReceivedOctets

Counter32

Read-only

Number of octets received over this virtual circuit since it was created.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.32.2.1.10

frCircuitCreationTime

TimeStamp

Read-only

The value of sysUpTime when the virtual circuit was created, whether by the Data Link Connection Management Interface or by a SetRequest.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.32.2.1.11

frCircuitLastTimeChange

TimeStamp

Read-only

The value of sysUpTime when last there was a change in the virtual circuit state

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.10.32.2.1.12

frCircuitCommittedBurst

Integer32

(0..2147483647)

Read-create

This variable indicates the maximum amount of data, in bits, that the network agrees to transfer under normal conditions, during the measurement interval. This object cannot be set because of structure and implementation limitations.

Currently, the maximum access is Read-only.

1.3.6.1.2.1.10.32.2.1.13

frCircuitExcessBurst

Integer32

(0..2147483647)

Read-create

This variable indicates the maximum amount of uncommitted data bits that the network will attempt to deliver over the measurement interval.

By default, if not configured when creating the entry, the Excess Information Burst Size is set to the value of ifSpeed.

This object cannot be set because of structure and implementation limitations.

Currently, the maximum access is read-only.

1.3.6.1.2.1.10.32.2.1.14

frCircuitThroughput

Integer32

(0..2147483647)

Read-create

Throughput is the average number of 'Frame Relay Information Field' bits transferred per second across a user network interface in one direction, measured over the measurement interval.

If the configured committed burst rate and throughput are both non-zero, the measurement interval T=frCircuitCommittedBurst/frCircuitThroughput.If the configured committed burst rate and throughput are both zero, the measurement in- terval T=frCircuitExcessBurst/ifSpeed.This object cannot be set because of structure and implementation limitations.

Currently, the maximum access is read-only.

Creation Restriction

This table does not support the SET operation. When a VC is created, this table is generated automatically.

Modification Restriction

The entries in this table can be modified.

Deletion Restriction

The entries in this table cannot be deleted. When the VC is torn down, this table is automatically deleted.