MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPbxCallerChgTable

hwEntPbxCallerChgTable

This table configures the calling number discrimination, hides calling numbers, or displays the same calling number for all outgoing calls.

The indexes of this table are hwEntPbxCallerChgEnterprise, hwEntPbxCallerChgDnset, hwEntPbxCallerChgCentrex, hwEntPbxCallerChgCountryCode, hwEntPbxCallerChgAreaCode, and hwEntPbxCallerChgCallerNum.

The table entry of this table is hwEntPbxCallerChgEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.3.6.1.4.1.2011.5.25.313.16.1.1

hwEntPbxCallerChgEnterprise

OCTET STRING

This object indicates an enterprise name.

Length: a string of 1 to 32 characters

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.16.1.2

hwEntPbxCallerChgDnset

OCTET STRING

This object indicates the DN set.

Length: a string of 1 to 32 characters

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.16.1.3

hwEntPbxCallerChgCentrex

OCTET STRING

This object indicates the Centrex group ID.

Length: a string of 1 to 32 digits

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.16.1.4

hwEntPbxCallerChgCountryCode

OCTET STRING

This object indicates the country or region code.

Length: a string of 1 to 4 digits

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.16.1.5

hwEntPbxCallerChgAreaCode

OCTET STRING

This object indicates the area code.

Length: a string of 1 to 8 digits

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.16.1.6

hwEntPbxCallerChgCallerNum

OCTET STRING

This object indicates the calling number.

Length: a string of 1 to 24 digits

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.16.1.7

hwEntPbxCallerChgRowStatus

RowStatus

This object indicates the row status.

The options are as follows:

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy
NOTE:

At present, only createAndGo and destroy are supported.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.16.1.8

hwEntPbxCallerChgChangeType

INTEGER

This object indicates the change type.

The options are as follows:

  • 1: ewDnset
  • 2: ewCentrex
  • 3: ewDnsetCentrex
  • 4: ewCountryCode
  • 5: ewAreaCode
  • 6: ewCountryAreaCode
  • 7: ewEnterpriseDnsetCentrex

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.16.1.9

hwEntPbxCallerChgNewDnSet

OCTET STRING

This object indicates the new DN set.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.16.1.10

hwEntPbxCallerChgNewCentrex

OCTET STRING

This object indicates the new Centrex group ID.

Length: a string of 1 to 32 digits

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.16.1.11

hwEntPbxCallerChgNewCountryCode

OCTET STRING

This object indicates the new country or region code.

Length: a string of 1 to 4 digits

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.16.1.12

hwEntPbxCallerChgNewAreaCode

OCTET STRING

This object indicates the new area code.

Length: a string of 1 to 8 digits

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.16.1.13

hwEntPbxCallerChgNewEnterprise

OCTET STRING

This object indicates the new enterprise name.

Length: a string of 1 to 32 characters

read-create

current

Creation Restriction

  • To create an entry, set a value for hwEntPbxCallerChgChangeType.
  • Only one change type can be configured a calling number.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

None.