MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPbxUserTable

hwEntPbxUserTable

This table is used to configure and maintain PBX users of different types.

The index of this table is hwEntPbxUserName.

The table entry of this table is hwEntPbxUserEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.1

hwEntPbxUserName

OCTET STRING

This object indicates the PBX user name.

Length: a string of 1 to 32 characters

not-accessible

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.2

hwEntPbxUserRowStatus

RowStatus

This object indicates the row status.

This object indicates the row status.

The options are as follows:

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy
NOTE:

At present, only createAndGo and destroy are supported.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.3

hwEntPbxUserType

INTEGER

This object indicates the user type.

The options are as follows:

  • 1: sipue
  • 2: sipueSub
  • 3: pots
  • 4: potsSub
  • 5: bra
  • 6: braSub

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.4

hwEntPbxUserPrivateId

OCTET STRING

This object indicates the user private ID.

Length: a string of 1 to 64 digits

NOTE:

If the user type is not set to sipue, the value is a string containing the slot ID, subcard ID, and port number.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.5

hwEntPbxUserEnterprise

OCTET STRING

This object indicates an enterprise name.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.6

hwEntPbxUserCountryCode

OCTET STRING

This object indicates the country or region code.

Length: a string of 1 to 4 digits

NOTICE:

The object is invalid in V200R005.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.7

hwEntPbxUserAreaCode

OCTET STRING

This object indicates the area code.

Length: a string of 1 to 8 digits

NOTICE:

The object is invalid in V200R005.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.8

hwEntPbxUserTelno

OCTET STRING

This object indicates the user service number.

Length: a string of 1 to 24 digits

NOTICE:

The value consists of 1 to 16 digits in V200R005.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.9

hwEntPbxUserKind

INTEGER

This object indicates the user type.

The options are as follows:

  • 1: commonUser
  • 2: telephonist
  • 3: priorityUser
  • 4: voiceData
  • 5: testUser
  • 6: payUser
  • 7: prepayUser
NOTICE:

The object is invalid in V200R005.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.10

hwEntPbxUserStatus

INTEGER

This object indicates the user status.

The options are as follows:

  • 1: normal
  • 2: arrear
  • 3: forbidden
  • 4: arrearForbidden

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.11

hwEntPbxUserCentrex

OCTET STRING

This object indicates the user Centrex group.

Length: a string of 1 to 32 characters

NOTE:

The hyphen (-) indicates that the user does not belong to any Centrex group.

The object is not supported after V200R005.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.12

hwEntPbxUserCentrexNumber

OCTET STRING

This object indicates the extension number in a Centrex group.

Length: a string of 1 to 8 digits

NOTE:

This object must be configured if hwPbxUserCentrex is not empty. The object is not supported in V200R005.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.13

hwEntPbxUserDnSet

OCTECT STRING

This object indicates the DN set.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.14

hwEntPbxUserInRight

INTEGER

This object indicates the incoming call permission.

The options are as follows:

  • 1: internal
  • 2: local
  • 3: nationalToll
  • 4: internationalToll
  • 5: noRight

Default value: 2

NOTE:

This object is not supported currently and has been transferred to the hwEntPbxUserInRight xxxx object.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.15

hwEntPbxUserOutRight

INTEGER

This object indicates the outgoing call permission.

The options are as follows:

  • 1: internal
  • 2: local
  • 3: nationalToll
  • 4: internationalToll
  • 5: noRight

Default value: 2

NOTE:

This object is not supported currently and has been transferred to the hwEntPbxUserOutRight xxxx object.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.16

hwEntPbxUserNewServiceRight

BITS

This object indicates whether a new service right is supported.

A maximum of 80 bits can be configured. Each bit represents a service permission.

0: unsupported

1: supported

The new service rights are as follows:

  • bit0: CLIP
  • bit1: CLIR
  • bit2: CW
  • bit3: CT
  • bit4: CallHold
  • bit5: CRBT
  • bit6: DLC
  • bit7: ThreeParty
  • bit8: QueryDN
  • bit9: pickupingroup
  • bit10: pickupspecial
  • bit11: abbdial
  • bit12: callIntercept
  • bit13: CBA
  • bit14: CCBS
  • bit15: CCNR
  • bit16: CFB
  • bit17: CFNR
  • bit18: CFO
  • bit19: CFU
  • bit20: CR
  • bit21: DND
  • bit22: ICM
  • bit23: InstantConference
  • bit24: MW
  • bit25: OCM
  • bit26: OverStepCLIR
  • bit27: Park
  • bit28: PWCB
  • bit29: RAC
  • bit30: RCS
  • bit31: RemoteOffice
  • bit32: RingService
  • bit33: Roam
  • bit34: SCA
  • bit35: SCCCancle
  • bit36: SCR
  • bit37: WakeCall
  • bit38 to bit63: reserved

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.17

hwEntPbxUserNewServiceActive

BITS

This object indicates whether a new service is activated for a user.

A maximum of 64 bits can be configured. Each bit represents a service permission.

0: inactivated

1: activated

bit0: PWCB

bit1: CW

bit2: DLC

bit3 to bit31: reserved

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.18

hwEntPbxUserMsnIndex

Integer32

This object indicates the default display number index when the multiple subscriber number (MSN) service is configured.

Value range: 0 to 255

NOTE:

This object cannot be configured for non-MSN-sub users.

The object is not supported in V200R005.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.19

hwEntPbxUserPassWordType

INTEGER

This object indicates the password type.

The options are as follows:

  • 1: simple
  • 2: cipher

This object must be configured when you configure hwEntPbxUserPassWord.

NOTE:

This object is dedicated to SIP UE users. The password type must be set to cipher. The value simple is not supported any more.

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.20

hwEntPbxUserPassWord

OCTET STRING

This object indicates the user password.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.21

hwEntPbxUserRegState

INTEGER

This object indicates the user registration status.

The options are as follows:

  • 1: outService
  • 2: inService

read-only

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.22

hwEntPbxUserSrvState

INTEGER

This object indicates the user service status.

The options are as follows:

  • 1: idle
  • 2: busy
  • 3: block

read-only

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.23

hwEntPbxUserLongDn

OCTET STRING

This object indicates the user long number.

Length: a string of 1 to 32 digits

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.24

hwEntPbxUserPwd

OCTET STRING

This object indicates the web self-service password.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.25

hwEntPbxUserInRightInner

INTEGER

This object indicates whether to enable the trunk-based intra-office incoming call permission.

The options are as follows:

  • 1: disable
  • 2: enable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.26

hwEntPbxUserInRightLocal

INTEGER

This object indicates whether to enable the trunk-based local incoming call permission.

The options are as follows:

  • 1: disable
  • 2: enable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.27

hwEntPbxUserInRightDdd

INTEGER

This object indicates whether to enable the trunk-based incoming Direct Distance Dialing (DDD) permission.

The options are as follows:

  • 1: disable
  • 2: enable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.28

hwEntPbxUserInRightIdd

INTEGER

This object indicates whether to enable the trunk-based incoming International Direct Dialing (IDD) permission.

The options are as follows:

  • 1: disable
  • 2: enable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.29

hwEntPbxUserOutRightInner

INTEGER

This object indicates whether to enable the intra-office outgoing call permission.

The options are as follows:

  • 1: disable
  • 2: enable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.30

hwEntPbxUserOutRightLocal

INTEGER

This object indicates whether to enable the local outgoing call permission.

The options are as follows:

  • 1: disable
  • 2: enable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.31

hwEntPbxUserOutRightDdd

INTEGER

This object indicates whether to enable the outgoing DDD permission.

The options are as follows:

  • 1: disable
  • 2: enable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.32

hwEntPbxUserOutRightIdd

INTEGER

This object indicates whether to enable the outgoing IDD permission.

The options are as follows:

  • 1: disable
  • 2: enable

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.33

hwEntPbxUserTelnoPassword

OCTET STRING

This object indicates the service password.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.3.6.1.4.1.2011.5.25.313.10.1.34

hwEntPbxUserPriorityValue

INTEGER

This object indicates the user level.

The options are as follows:

  • 1: default
  • 2: normal
  • 3: advanced
  • 4: super

read-create

current

Creation Restriction

To create an entry, set values for the following objects: hwEntPbxUserType, hwEntPbxUserPrivateId, hwEntPbxUserEnterpriseName, hwPbxUserTelno, hwEntPbxUserDnSet, and hwPbxUserCentrex.

Modification Restriction

  1. The following objects cannot be modified: hwEntPbxUserType, hwEntPbxUserPrivateId, hwEntPbxUserEnterpriseName, hwPbxUserTelno, hwPbxUserCountryCode, and hwPbxUserAreaCode.
  2. The entries in this table cannot be modified when the user is busy.
  3. The default value of hwEntPbxUserPwd is huawei@123. The resetpassword can be delivered for resetting the existing password.
  4. The default value of hwEntPbxUserTelnoPassword is 123456. The value of hwEntPbxUserTelnoPassword must consist of six digits. The resetpassword (case-insensitive) can be delivered for resetting the existing password.

Deletion Restriction

The entries in this table cannot be deleted when the user is busy.