No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwFlhSyncTable

hwFlhSyncTable

This table contains information about the attibute of synchronization operation. You can configure the synchronization operation for local files by using this table.

The index of this table is hwFlhSyncIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.9.1.2.2.1.1

hwFlhSyncIndex

Integer (1..2147483647)

Not-Accessible

The value of the object identifies the index of the table.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.9.1.2.2.1.2

hwFlhSyncType

Integer{net2FlashCopy(1)}

Read-create

The value of the object identifies the operation of the files copy.

The object has the following value:

  • net2FlashCopy(1): copy a file from one board to another.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.9.1.2.2.1.3

hwFlhSyncRange

Integer {designate (1), all (2)}}

Read-create

The value of the object identifies the synchronization range of the files.

The object has the following values:

  • designate (1): copy from one board to another board.

  • all (2): copy in batch.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.9.1.2.2.1.4

hwFlhSyncSourcePath

Octet String (SIZE (1..32))

Read-create

The source path.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.9.1.2.2.1.5

hwFlhSyncSourceFile

Octet String (SIZE (1..255))

Read-create

The source file name. Currently, the value can be an integer ranging from 1 to 64.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.9.1.2.2.1.6

hwFlhSyncDestinationPath

Octet String (SIZE (1..32))

Read-create

The destination path.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.9.1.2.2.1.7

hwFlhSyncDestinationFile

Octet String (SIZE (1..32))

Read-create

The destination file name. Currently, the value can be an integer ranging from 1 to 64.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.9.1.2.2.1.8

hwFlhSyncRowStatus

RowStatus

Read-create

This object indicates the row status of this table.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

None.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

None.

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 122212

Downloads: 683

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next