No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntServiceNumTable

hwEntServiceNumTable

This table is used to bind DSP templates with service numbers.

The index of this table is hwEntServiceNumMap.

The table entry of this table is hwEntServiceNumEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.253.7.1.1

hwEntServiceNumMap

OCTET STRING

This object indicates a service number.

Length: a string of 1 to 64 digits

not-accessible

current

1.3.6.1.4.1.2011.5.25.253.7.1.2

hwEntServiceNumDspTemplate

OCTET STRING

This object indicates the name of a DSP parameter template.

Length: a string of 1 to 31 characters

read-create

current

1.3.6.1.4.1.2011.5.25.253.7.1.3

hwEntServiceNumRowStatus

RowStatus

This object indicates the row status.

The options are as follows:

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy
NOTE:

At present, only createAndGo and destroy are supported.

read-create

current

Creation Restriction

You can configure a maximum of 64 entries in the table. When you create an entry, hwEntServiceNumRowStatus and hwEntServiceNumDspTemplate must be configured at the same time.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

None.