Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
nqaScheduleTable

nqaScheduleTable

nqaScheduleTable is the task scheduling table of the test instance. It is used to reduce the burden on devices when tests are performed concurrently and schedule the test instances. Test instance scheduling covers the following aspect:

  • Setting the start time of a test instance

  • Setting the end time of a test instance

  • Auto-delivering the start time and test interval when several tasks are started concurrently

The indexes of this table are nqaAdminCtrlOwnerIndex and nqaAdminCtrlTestName.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.111.2.3.1.1

nqaScheduleStartType

INTEGER{

default(0),

startNow(1),

startAt(2),

startAfter(3),

startDaily(4)

}

Read-write

The value of this object identifies the start mode of a test instance.

The value default(0) can only be read but cannot be configured.

1.3.6.1.4.1.2011.5.25.111.2.3.1.2

nqaScheduleStartTime

Unsigned32

Read-write

This object indicates the start time of a test instance.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.111.2.3.1.3

nqaScheduleEndType

INTEGER

  • default(0)
  • endAt(1)
  • endAfter(2)
  • endLifetime(3)

Read-write

The value of this object identifies the end mode of a test instance.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.111.2.3.1.4

nqaScheduleEndTime

Unsigned32

Read-write

This object indicates the end time of a test instance.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.111.2.3.1.5

nqaScheduleAgeTime

Integer32

Read-write

The value of this object identifies the aging time. Setting the value to 0 indicates reserving the test instance eternally.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.111.2.3.1.7

nqaScheduleNumOfInitiations

Integer32

Read-only

The value of this object identifies the number of times to start a test instance. This object is used as the index of the result table, HTTP statistics table, jitter statistics table, FTP statistics table and history table.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.111.2.3.1.8

nqaScheduleLastFinishIndex

Integer32

Read-only

The value of this object identifies the index of the lately finished tests in nqaResultsTable.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.111.2.3.1.9

nqaScheduleOperStatus

INTEGER

  • reset(1)
  • stop(2)
  • restart(3)
  • active(4)
  • inactive(5)

Read-write

The value of this object identifies the status of the scheduling operation.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.111.2.3.1.10

nqaScheduleLastCollectIndex

INTEGER

Read-only

The value of this object identifies the index of the collection table that is lately finished by the instance tests.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

No entry can be created in this table.

Modification Restriction

  • When a test instance is in the inactive status, only read-create single objects can be modified.

  • The setting of nqaScheduleAgeTime needs to be delivered separately. This object cannot be bound with other scheduling objects to be delivered together with them. When a test instance is running, you cannot set nqaScheduleAgeTime. To set this object, you must stop the test instance first.

  • The setting of nqaScheduleOperStatus needs to be deployed separately. This object cannot be bound with other scheduling objects to be delivered together with them. When the value of this object is active(4) or inactive(5), the value cannot be set. To reset this object, you must stop the running test instance first. You can set the object to the value stop(2) or restart(3) no matter whether the test is running or not.

  • Objects nqaScheduleStartType, nqaScheduleStartTime, nqaScheduleEndType, and nqaScheduleEndTime in the scheduling table can be delivered together (The end mode objects must be delivered together with the start mode objects). You cannot set the preceding objects when the test instance is running. To set these objects, you must stop the test instance first.

  • When the start mode is startNow(1), the value must be 0. The end mode has four values: When the end mode is endAt(1), the value must be longer than the time (the seconds from 1970 to now) plus five seconds; when the end mode is endAfter(2) or endLifetime(3), the value must be less than 86400 but five seconds longer than the start time; the fourth value is default(0).

  • When the start mode is startAt(2), the value must not be shorter than the time (the seconds from 1970 to now) plus five seconds. The end mode has four values: When the end mode is endAt(1), the value must be five seconds longer the start time; when the end mode is endAfter(2), the end time must be less than 86400 but longer than the offset between the value start time plus five seconds and the seconds from 1970 to now; when the end mode is endLifetime(3), the value must be less than 86400 but five seconds longer than the start time; the fourth value is default(0).

  • When the start mode is startAfter(3), the value must range from 0 (longer than 0) to 86400. The end mode has four values: When the end mode is endAt(1), the value must longer than the sum of start time plus five seconds and the seconds from 1970 to now; when the end mode is endAfter(2), the value must be shorter than 86400 but longer than the start time plus five seconds; when the end mode is endLifetime(3), the value must be less than 86400 but five minutes longer than the start time; the fourth value is default(0).

  • If the value of nqaGroupStatusType in nqaGroupTable for a test instance is member(2), that is, if the test instance is a group member, you cannot set the following objects:

    • nqaScheduleStartType

    • nqaScheduleStartTime

    • nqaScheduleEndType

    • nqaScheduleEndTime

  • That is, a group member cannot be scheduled. You cannot set the value of nqaScheduleOperStatus as restart(3) or set nqaScheduleAgeTime.

  • If the value of nqaGroupStatusType in nqaGroupTable for a test instance is leader(1), that is, if the test instance is a group leader, you cannot set the value of nqaScheduleOperStatus as restart(3) or set nqaScheduleAgeTime.

  • To start a test instance, you must configure all the mandatory parameters.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 111385

Downloads: 673

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next