No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
isisCircLevelTable

isisCircLevelTable

Each instance of the isisCircLevelTable contains the certain layer information of an interface that is enabled by the local IS.

The external index of this table is isisSysInstance and isisCircIndex, and the index in this table is isisCircLevelIndex.

OID

Object

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.3.37.1.4.1.1.1

isisCircLevelIndex

Integer

Not-accessible

The level that this entry describes.

1 indicates Level-1 and 2 stands for Level-2.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.3.37.1.4.1.1.2

isisCircLevelMetric

DefaultMetric

Read-create

The metric value of this circuit for this level.

The value ranges from 1 to 63.

The default value of the loopback interface is 0, and the default values of the other interfaces are 10.

Currently, the maximum access is read-only.

1.3.6.1.3.37.1.4.1.1.3

isisCircLevelWideMetric

WideMetric

Read-create

The wide metric value of this circuit for this level.

The value ranges from 1 to 16777215. The default value is 10 by default.

Currently, the maximum access is read-only.

1.3.6.1.3.37.1.4.1.1.4

isisCircLevelISPriority

ISPriority

Read-create

The priority for becoming LAN Designated Intermediate System at this level.

The value ranges from 0 to 127. The default value is 64.

Currently, the maximum access is read-only.

1.3.6.1.3.37.1.4.1.1.5

isisCircLevelIDOctet

Integer32

Read-create

A one byte identifier that can be used in protocol packets to identify a circuit. Values of isisCircLevelIDOctet do not need to be unique. They are only required to differ on LANs where the Intermediate System is the Designated Intermediate System.

The value ranges from 0 to 255.

Currently, the maximum access is read-only.

1.3.6.1.3.37.1.4.1.1.6

isisCircLevelID

CircuitID

Read-only

The ID of the circuit allocated during initialization.

If no value has been negotiated (either because the adjacency is to an End System, or because initialization has not yet successfully completed), this object has the value which would be proposed for this circuit (that is the concatenation of the local system ID and the one byte isisCircLevelIDOctet for this circuit).

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.3.37.1.4.1.1.7

isisCircLevelDesIS

OctetString

Read-only

The ID of the LAN Designated Intermediate System on this circuit at this level. If, for any reason, this system is not partaking in the relevant Designated Intermediate System election process, then the value returned is the zero length OCTET STRING.

The value is 0 or 7.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.3.37.1.4.1.1.8

isisCircLevelHelloMultiplier

Integer32

Read-create

This value is multiplied by the corresponding HelloTimer and the result in seconds (rounded up) is used as the holding time in transmitted hellos, to be used by receivers of hello packets from this IS.

The value ranges from 3 to 1000 seconds. The default value is 3 seconds.

Currently, the maximum access is read-only. The value ranges from 3 to 1000.

1.3.6.1.3.37.1.4.1.1.9

isisCircLevelHelloTimer

Integer32

Read-create

Maximum period, in milliseconds, between IIH PDUs on multiaccess networks at this level for LANs. The value at level 1 is used as the period between Hellos on L1L2 point to point circuits. Setting this value at level 2 on an L1L2 point to point circuit will result in an error of InconsistentValue.

This object follows the resettingTimer behavior.

The value ranges from 3000 to 255000 milliseconds. The default value is 10000.

Currently, the maximum access is read-only.

1.3.6.1.3.37.1.4.1.1.10

isisCircLevelDRHelloTimer

Integer32

Read-create

Period, in milliseconds, between Hello PDUs on multiaccess networks when this IS is the Designated Intermediate System. This object follows the resettingTimer behavior.

The value ranges from 1000 to 85000 milliseconds. By default, it is 3000 milliseconds. The value cannot be configured by command.

Currently, the maximum access is read-only.

1.3.6.1.3.37.1.4.1.1.11

isisCircLevelLSPThrottle

Unsigned32

Read-create

Minimal interval of time, in milliseconds, between transmissions of LSPs on an interface at this level.

The value ranges from 1 to 10000, in milliseconds. By default, it is 50 milliseconds.

Currently, the maximum access is read-only.

1.3.6.1.3.37.1.4.1.1.12

isisCircLevelMinLSPRetransInt

Integer32

Read-create

Minimum interval, in seconds, between re-transmission of an LSP at this level. This object follows the resettingTimer behavior.

Note that isisCircLevelLSPThrottle controls how fast we send back to back LSPs. This variable controls how fast we re-send the same LSP.

The value ranges from 1 to 300 seconds.

The default value is 5 seconds.

Currently, the maximum access is read-only.

1.3.6.1.3.37.1.4.1.1.13

isisCircLevelCSNPInterval

Integer32

Read-create

Interval of time, in seconds, between periodic transmission of a complete set of CSNPs on multiaccess networks if this device is the Designated Interdiate System at this level.

The value ranges from 1 to 65535. By default, it is 10.

Currently, the maximum access is read-only. The value ranges from 1 to 65535.

1.3.6.1.3.37.1.4.1.1.14

isisCircLevelPartSNPInterval

Integer32

Read-create

Minimum interval in seconds between sending Partial Sequence Number PDUs at this level. This object follows the resettingTimer behavior.

The value ranges from 1 to 120. The default value is 2. It cannot set by commands.

Currently, the maximum access is read-only.

Creation Restriction

The entries in this table cannot be created.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

None.

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 127567

Downloads: 688

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next