Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntBraUserConfigTable

hwEntBraUserConfigTable

This table is used to add, modify, delete, and query BRA users.

The index of this table is hwEntBraUserName.

The table entry of this table is hwEntBraUserConfigEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.251.3.1.1

hwEntBraUserName

OCTET STRING

This object indicates a user name.

Length: a string of 1 to 32 characters

not-accessible

current

1.3.6.1.4.1.2011.5.25.251.3.1.2

hwEntBraUserPort

Integer32

This object indicates a user port number.

read-create

current

1.3.6.1.4.1.2011.5.25.251.3.1.3

hwEntBraUserMgId

Integer32

This object indicates an interface ID.

Value range: 0 to 16777215

This object does not have a default value.

NOTE:

This object is specified when a user is added.

read-create

current

1.3.6.1.4.1.2011.5.25.251.3.1.4

hwEntBraUserTelNo

OCTET STRING

This object indicates a user's phone number.

Length: a string of 0 to 32 digits

This object does not have a default value.

NOTE:

The phone number is configured by the BRA user.

read-create

current

1.3.6.1.4.1.2011.5.25.251.3.1.5

hwEntBraUserUserGroupId

OCTET STRING

This object indicates a user group name.

Value range: 0 to 32

This object does not have a default value.

read-create

current

1.3.6.1.4.1.2011.5.25.251.3.1.6

hwEntBraUserRowStatus

RowStatus

This object indicates the row status.

The options are as follows:

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy
NOTE:

At present, only createAndGo and destroy are supported.

read-create

current

1.3.6.1.4.1.2011.5.25.251.3.1.7

hwEntBraUserPriority

INTEGER

This object indicates a user priority.

The options are as follows:

  • 1: cat1
  • 2: cat2
  • 3: cat3

Default value: cat3

read-create

current

1.3.6.1.4.1.2011.5.25.251.3.1.8

hwEntBraUserUniErrReport

INTEGER

This object indicates whether to report a UNI fault.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: disable

NOTE:

If this object is set to enable, a user service ends when a UNI fault occurs on the port.

read-create

current

1.3.6.1.4.1.2011.5.25.251.3.1.9

hwEntBraUserAutoResumeLimit

Integer32

This object indicates the maximum number of times that a service can be automatically restored.

Value range: 0 to 255

Default value: 20

NOTE:

Value 0 indicates that services cannot be automatically restored. Value 255 indicates that a service can be restored for an unlimited number of times.

read-create

current

Creation Restriction

When configuring an entry, you must configure the user port number and interface ID at the same time.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

None.

Translation
Download
Updated: 2019-06-05

Document ID: EDOC1000097213

Views: 97621

Downloads: 648

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next