MIB Reference

AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R007

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwApLineatePortTable(for AC)

hwApLineatePortTable(for AC)

This table is used to query the attributes of wired ports on an AP and modify the description of wired ports. No entry in this table can be created or deleted.

The indexes of this table are hwApIndex and hwApLineatePortIndex.

OID

Object Name

Syntax

Description

Access

Status

1.3.6.1.4.1.2011.6.139.2.6.2.1.1

hwApLineatePortIndex

Integer32

This object indicates the index of a wired port on an AP.

Not-accessible

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.2

hwApLineatePortType

Integer

This object indicates the type of a wired port on an AP.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.3

hwApLineatePortDesc

Octet string

This object indicates the description of a wired port on an AP.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.4

hwApLineatePortState

Integer

This object indicates the status of a wired port on an AP.

Read-only

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.5

hwApLineatePortSpeed

Integer32

This object indicates the transmission rate of a wired port on an AP, in Mbit/s.

Read-only

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.6

hwApLineatePortIpAddress

IpAddress

This object indicates the IP address of a wired port on an AP.

Read-only

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.7

hwApLineatePortMacAddress

INTEGER

This object indicates the MAC address of a wired port on an AP.

Read-only

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.8

hwApMultiLineatePortMode

Integer32

This object indicates the working mode of the AP port:
  • root(1): root mode
  • endpoint(2): endpoint mode
By default, the AP port works in root mode.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.9

hwApMultiLineatePortUserIsolate

Integer32

This object indicates whether user isolation is enabled on ports.
  • disable(1): user isolation is enabled on ports.
  • enable(2): user isolation is disabled on ports.
By default, user isolation is disabled on ports.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.10

hwApMultiLineatePortStpEnable

Integer32

This object indicates whether STP is enabled on ports.
  • disable(1): STP is enabled on ports.
  • enable(2): STP is disabled on ports.
By default, STP is disabled on ports.

APs with two GE ports support the object only when the two ports are not bound to an Eth-Trunk port.

Read-only

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.11

hwApMultiLineatePortVlanTagged

OCTET STRING

This object indicates whether a tagged VLAN ID is configured on the port. By default, no tagged VLAN ID is configured on the port.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.12

hwApMultiLineatePortVlanUntagged

OCTET STRING

This object indicates whether an untagged VLAN ID is configured on the port. By default, no untagged VLAN ID is configured on the port.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.13

hwApMultiLineatePortPvidVlan

Integer32

This object indicates whether a PVID VLAN is configured on the port. By default, no PVID VLAN is configured on the port.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.14

hwApMultiLineatePortCRCErrorHighThreshold

Integer32

The value of this object identifies the alarm threshold for CRC errors.

Read-only

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.15

hwApMultiLineatePortCRCErrorLowThreshold

Integer32

The value of this object identifies the clear alarm threshold for CRC errors.

Read-only

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.16

hwApMultiLineatePortCRCErrorSwitch

Integer32

This object indicates the alarm function for CRC errors.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.17

hwApLineatePortAclNumInbound

Integer32

The value of this object identifies the number of the ACL configured to filter incoming IPv4 packets on a wired port of an AP.

The value ranges from 3000 to 3031 or from 4000 to 4031.

NOTE:

This object is valid only when it is set together with the hwApLineatePortAclSwitchInbound object.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.18

hwApLineatePortAclNumOutbound

Integer32

The value of this object identifies the number of the ACL configured to filter outgoing IPv4 packets on a wired port of an AP.

The value ranges from 3000 to 3031 or from 4000 to 4031.

NOTE:

This object is valid only when it is set together with the hwApLineatePortAclSwitchOutbound object.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.19

hwApLineatePortAclNameInbound

OCTET STRING

This object indicates the name of the ACL configured to filter incoming IPv4 packets on a wired port of an AP.

The value is a string of 1 to 31 characters.

NOTE:

This object is valid only when it is set together with the hwApLineatePortAclSwitchInbound object.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.20

hwApLineatePortAclNameOutbound

OCTET STRING

This object indicates the name of the ACL configured to filter outgoing IPv4 packets on a wired port of an AP.

The value is a string of 1 to 31 characters.

NOTE:

This object is valid only when it is set together with the hwApLineatePortAclSwitchOutbound object.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.21

hwApLineatePortAclSwitchInbound

Integer32

The value of this object identifies whether to enable IPv4 packet filtering in the inbound direction on a wired port of an AP.
  • disabled(1): disable IPv6 packet filtering in the inbound direction.
  • enabled(2): enable IPv6 packet filtering in the inbound direction.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.22

hwApLineatePortAclSwitchOutbound

Integer32

The value of this object identifies whether to enable IPv4 packet filtering in the outbound direction on a wired port of an AP.
  • disabled(1): disable IPv6 packet filtering in the outbound direction.
  • enabled(2): enable IPv6 packet filtering in the outbound direction.

Read-write

Current

1.3.6.1.4.1.2011.6.139.2.6.2.1.29

hwApMultiLineatePortIsAddInTrunk

INTEGER

The value of this object identifies whether the AP wired port is added to a trunk.
  • 0: the AP wired port is removed from a trunk.
  • 1: the AP wired port is added to a trunk.

Read-only

Current

Creation Restriction

No entry in this table can be created.

Modification Restriction

None.

Deletion Restriction

No entry in this table can be deleted.

Access Restriction

None.

Translation
Download